ELEC
8-17
61U5H11
Electrical system
Checking the hour meter
1.
Disconnect the hour meter coupler from
the wiring harness.
2.
Connect the positive battery lead to the
yellow (Y) terminal
a
, also connect the
negative battery lead to the black (B) ter-
minal
b
, and then check that the hour
meter displayed the all segments which
has been illuminated for 2 seconds.
Replace the hour meter if there is no illu-
minated.
61U80160
a
b
61U5H11_08 05.10.7 3:02 PM Page 18
Содержание 115B
Страница 1: ...115B SERVICE MANUAL 61U 28197 5H 11 140B E115A E115A 115B 140B ...
Страница 4: ......
Страница 79: ...61U5H11 4 18 9 8 7 6 5 4 3 2 1 MEMO ...
Страница 136: ...POWR 5 55 61U5H11 Power unit MEMO ...
Страница 159: ...61U5H11 6 22 9 8 7 6 5 4 3 2 1 Shimming Shimming 6G46090E T3 M3 M4 M1 M2 T1 T2 F R P ...
Страница 255: ......
Страница 256: ...YAMAHA MOTOR CO LTD Printed in Japan Oct 2005 1 2 1 E_1 Printed on recycled paper E115A 115B 140B ...