Page 115
FT-950 O
PERATING
M
ANUAL
073 SCP 1.8 FIX
Function
: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 160 m amateur
band.
Available Values
: 1.800 ~ 1.999 MHz (1 kHz steps)
Default Setting
: 1.800 MHz
074 SCP 3.5 FIX
Function
: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 80 m amateur
band.
Available Values
: 3.500 ~ 3.999 MHz (1 kHz steps)
Default Setting
: 3.500 MHz
075 SCP 5.2 FIX
Function
: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 60 m amateur
band.
Available Values
: 5.250 ~ 5.499 MHz (1 kHz steps)
Default Setting
: 5.250 MHz
076 SCP 7.0 FIX
Function
: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 40 m amateur
band.
Available Values
: 7.000 ~ 7.299 MHz (1 kHz steps)
Default Setting
: 7.000 MHz
077 SCP 10.1 FIX
Function
: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 30 m amateur
band.
Available Values
: (1)0.100 ~ (1)0.149 MHz (1 kHz steps)
Default Setting
: (1)0.100 MHz
078 SCP 14.0 FIX
Function
: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 20 m amateur
band.
Available Values
: (1)4.000 ~ (1)4.349 MHz (1 kHz steps)
Default Setting
: (1)4.000 MHz
M
ENU
M
ODE
SCOPE G
ROUP
A
DVICE
:
This group’s adjustment has no effect if the optional
DMU-2000
Data Management Unit is not connected.
079 SCP 18.0 FIX
Function
: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 17 m amateur
band.
Available Values
: (1)8.000 ~ (1)8.199 MHz (1 kHz steps)
Default Setting
: (1)8.068 MHz
080 SCP 21.0 FIX
Function
: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 15 m amateur
band.
Available Values
: (2)1.000 ~ (2)1.449 MHz (1 kHz steps)
Default Setting
: (2)1.000 MHz
081 SCP 24.8 FIX
Function
: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 12 m amateur
band.
Available Values
: (2)4.800 - (2)4.989 MHz (1 kHz steps)
Default Setting
: (2)4.890 MHz
082 SCP 28.0 FIX
Function
: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 10 m amateur
band.
Available Values
: (2)8.000 ~ (2)9.699 MHz (1 kHz steps)
Default Setting
: (2)8.000 MHz
083 SCP 50.0 FIX
Function
: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 6 m amateur band.
Available Values
: (5)0.000 ~ (5)3.999 MHz (1 kHz steps)
Default Setting
: (5)0.000 MHz