background image

Page 106

FT-950 O

PERATING

 M

ANUAL

G

ROUP

N

O

. M

ENU

 F

UNCTION

A

VAILABLE

 V

ALUES

D

EFAULT

 S

ETTING

MODE-DATA

050 DATA DT GAIN

0 ~ 100

50

MODE-DATA

051 DATA OUT LVL

0 ~ 100

50

MODE-DATA

052 DATA VOX DLY

30 ~ 3000 msec (10 msec/step)

300 msec

MODE-DATA

053 DATA V GAIN

0 ~ 100

50

MODE-DATA

054 DATA PKTDISP

–3000 ~ +3000 Hz (10 Hz/step)

0 Hz

MODE-DATA

055 DATA PKT SFT

–3000 ~ +3000 Hz (10 Hz/step)

1000 Hz

MODE-FM

056 F3E MIC

Ur/0 ~ 100

50

MODE-FM

057 F3E 28 RPT

0 ~ 1000 kHz (10 kHz/step)

100 kHz

MODE-FM

058 F3E 50 RPT

0 ~ 4000 kHz (10 kHz/step)

1000 kHz

MODE-RTTY

059 RTTY R PLRTY

nor/rEV (NORMAL/REVERSE)

nor (NORMAL)

MODE-RTTY

060 RTTY T PLRTY

nor/rEV (NORMAL/REVERSE)

nor (NORMAL)

MODE-RTTY

061 RTTY OUT LVL

0 ~ 100

50

MODE-RTTY

062 RTTY SHIFT

170/200/425/850 Hz

170 Hz

MODE-RTTY

063 RTTY TONE

1275/2125 Hz

2125 Hz

MODE-SSB

064 J3E TX BPF

1-30/1-29/2-28/3-27/4-26

3-27

 (300 ~ 2700 Hz)

MODE-SSB

065 J3E LSB CAR

–200 Hz ~ +200 Hz (10 Hz/steps)

0 Hz

MODE-SSB

066 J3E USB CAR

–200 Hz ~ +200 Hz (10 Hz/steps)

0 Hz

RX GENERAL 067 RGEN NB 1 LVL

0 ~ 255

128

RX GENERAL 068 RGEN NB 2 LVL

0 ~ 255

128

RX GENERAL 069 RGEN CNTR LV

–40 ~ +20 dB

–15 dB

RX GENERAL 070 RGEN CNTR WI

1 ~ 11

10

RX GENERAL 071 RGEN DNF

OFF/On

OFF

RX GENERAL 072 RGEN DNR

OFF/1 ~ 15

OFF

SCOPE

073 SCP 1.8 FIX

1.800 ~ 1.999 MHz (1 kHz/steps)

1.800 MHz

Ú

1

SCOPE

074 SCP 3.5 FIX

3.500 ~ 3.999 MHz (1 kHz/steps)

3.500 MHz

Ú

1

SCOPE

075 SCP 5.2 FIX

5.250 ~ 5.499 MHz (1 kHz/steps)

5.250 MHz

Ú

1

SCOPE

076 SCP 7.0 FIX

7.000 ~ 7.299 MHz (1 kHz/steps)

7.000 MHz

Ú

1

SCOPE

077 SCP 10.1 FIX

(1)0.100 ~ (1)0.149 MHz (1 kHz/steps)

(1)0.100 MHz

Ú

1

SCOPE

078 SCP 14.0 FIX

(1)4.000 ~ (1)4.349 MHz (1 kHz/steps)

(1)4.000 MHz

Ú

1

SCOPE

079 SCP 18.0 FIX

(1)8.000 ~ (1)8.199 MHz (1 kHz/steps)

(1)8.068 MHz

Ú

1

SCOPE

080 SCP 21.0 FIX

(2)1.000 ~ (2)1.449 MHz (1 kHz/steps)

(2)1.000 MHz

Ú

1

SCOPE

081 SCP 24.8 FIX

(2)4.800 ~ (2)4.989 MHz (1 kHz/steps)

(2)4.890 MHz

Ú

1

SCOPE

082 SCP 28.0 FIX

(2)8.000 ~ (2)9.699 MHz (1 kHz/steps)

(2)8.000 MHz

Ú

1

SCOPE

083 SCP 50.0 FIX

(5)0.000 ~ (5)3.999 MHz (1 kHz/steps)

(5)0.000 MHz

Ú

1

TUNING

084 TUN DIALSTP

1/5/10 Hz

10 Hz

TUNING

085 TUN CW FINE

EnA/diS (ENABLE/DISABLE)

diS (DISABLE)

TUNING

086 TUN MHz SEL

1/0.1 MHz

1 MHz

TUNING

087 TUN AM STEP

2.5/5/9/10/12.5 kHz

5 kHz

TUNING

088 TUN FM STEP

5/6.25/10/12.5/20/25 kHz

5 kHz

TUNING

089 TUN FM DIAL

10/100 Hz

100 Hz

TUNING

090 TUN MY BAND

1.8 ~ 50/GE

M

ENU

 M

ODE

Ú

1: Requires optional 

DMU-2000

 Data Management Unit.

Содержание FT-950

Страница 1: ...lected Menu item 2 Rotate the SELECT knob to select the Menu item you wish to modify 3 Rotate the CLAR VFO B knob to change the cur rent setting of the selected Menu item ADVICE Press the CLEAR button...

Страница 2: ...T SEL bAnd rEG bAnd GENERAL 025 GENE BEP LVL 0 100 50 GENERAL 026 GENE CAT BPS 4800 9600 192H 19200 384H 38400 bps 4800 bps GENERAL 027 GENE CAT TOT 10 100 1000 3000 msec 10 msec GENERAL 028 GENE CAT...

Страница 3: ...RGEN CNTR LV 40 20 dB 15 dB RX GENERAL 070 RGEN CNTR WI 1 11 10 RX GENERAL 071 RGEN DNF OFF On OFF RX GENERAL 072 RGEN DNR OFF 1 15 OFF SCOPE 073 SCP 1 8 FIX 1 800 1 999 MHz 1 kHz steps 1 800 MHz 1 SC...

Страница 4: ...O 102 TAUD PE1 BW 1 10 2 TX AUDIO 103 TAUD PE2 FRQ OFF 700 1500 Hz 100 Hz step 800 Hz TX AUDIO 104 TAUD PE2 LVL 20 10 0 TX AUDIO 105 TAUD PE2 BW 1 10 1 TX AUDIO 106 TAUD PE3 FRQ OFF 1500 3200 Hz 100 H...

Страница 5: ...t has no effect 005 DISP DIM VFD Function Setting of the display brightness level Available Values 0 15 Default Setting 8 006 DISP BAR SEL Function Selects one of three parameters to be viewed on the...

Страница 6: ...50 ADVICE If the optional DVS 6 Voice Memory Unit is not connected this adjustment has no effect 015 DVS TX LVL Function Sets the microphone input level to the optional DVS 6 Voice Memory Unit Availab...

Страница 7: ...may enter the CW message from the CW keyer GENERAL GROUP 024 GENE ANT SEL Function Sets the method of antenna selection Available Values bAnd rEG Default Setting bAnd bAnd The antenna is selected in a...

Страница 8: ...gain for the AM mode Available Values Ur 0 100 Default Setting Ur When this menu is set to Ur you may adjust the micro phone gain using the front panel s MIC GAIN knob MODE CW GROUP 037 A1A F TYPE Fu...

Страница 9: ...044 A1A DELAY FuLL The transceiver will operate in the full break in QSK mode 044 A1A DELAY Function Adjusts the Keying Delay receiver recovery time on the CW mode Available Values 30 3000 msec 10 ms...

Страница 10: ...ack Available Values 0 100 Default Setting 50 062 RTTY SHIFT Function Selects the frequency shift for RTTY AFSK operation Available Values 170 200 425 850 Hz Default Setting 170 Hz 063 RTTY TONE Funct...

Страница 11: ...Hz 066 J3E USB CAR Function Adjusts the receiver carrier point for the USB mode Available Values 200 Hz 200 Hz 10 Hz steps Default Setting 0 Hz RX GENERAL GROUP 067 RGEN NB 1 LVL Function Adjusts the...

Страница 12: ...FIX mode Spectrum Scope while monitoring on the 20 m amateur band Available Values 1 4 000 1 4 349 MHz 1 kHz steps Default Setting 1 4 000 MHz MENU MODE SCOPE GROUP ADVICE This group s adjustment has...

Страница 13: ...o cancel the setting skipped Off d d d d d nota tion appears TX AUDIO GROUP 091 TAUD EQ1 FRQ Function Selects the center frequency of the lower range for the parametric microphone equalizer Available...

Страница 14: ...vailable Values 1 10 Default Setting 2 MENU MODE 103 TAUD PE2 FRQ Function Selects the center frequency of the middle range for the parametric microphone equalizer when the speech processor is activat...

Страница 15: ...f this frequency is restricted to sta tions operating in or near Alaska and only for emergency purposes never for routine operations See 97 401 c of the FCC s regulations for details TX GENERAL GROUP...

Отзывы: