31. HOURS_OFFSET=x
x - number of seconds, 0..10000000
Factory setting: 0
The number of seconds which are added to engine hours. Some users have replaced ECU and EDC modules,
which reports engine hours since installation of module. This setting helps to get real data on gauges.
32. J_PASS_PGN=x
x – empty or list of NMEA 2000 or J1939 PGNs separated by comma
Factory setting: empty
Forward specified messages from an NMEA 2000 network to an engine network. Some boats have trip/fuel
computers installed in the engine network that require NMEA 2000 speed data.
To forward speed through water (PGN 128259) and speed over ground with course (PGN 129026), add
the following line to the YDEG.TXT file (up to 20 PGNs can be specified):
J_PASS_PGN=128259,129026
33. J_PASS_ADDR=OFF|AS_IS|n
n – number from 0 to 253
Factory setting: 210
The network address is used to send messages to the engine’s network. Addresses below 180 can be
occupied by various devices. The OFF value turns off the forwarding of messages, with AS_IS messages
being forwarded as is (with the original sender address).
It is recommended to keep the factory setting if you have no reasons to change it.