background image

— 7 —

Device parameter

Value

Unit

Power supply voltage, from NMEA 2000 network

7..16

V

Reverse polarity protection (power supply)

Yes

Average current consumption without playback

50

mA

Average current during playback (sound 1, Appendix B; 13V / 4 Ohm)

200

mA

Maximum current during playback (sound 23, Appendix B; 13 V / 4 Ohm)

440

mA

Recommended speaker impedance

4..8

Ohm

Audio amplifier output (8 Ohm load at 13V)

10

W

Load Equivalency Number

20

LEN

Built-in current limiting resistor for the external LED

200

Ohm

External LED power supply

3,3

V

Operating temperature range

-40..+80

°С

Weight

37

g

Device case length (without connector)

54

mm

Cable length

400

mm

 

Yacht Devices Ltd declares that this product is compliant with the essential requirements of EMC 

directive 2014/30/EU and radio and TTE directive 1999/5/EC.

 

Dispose of this product in accordance with the WEEE Directive. Do not mix electronic waste with 

domestic or industrial refuse.

Содержание YDAB-01

Страница 1: ...User Manual Alarm Button YDAB 01 also covers models YDAB 01N YDAB 01R Firmware version 1 08 2022...

Страница 2: ...B 01 002 May 24 2022 Web http www yachtd com NMEA 2000 is a registered trademark of the National Marine Electronics Association SeaTalk NG is a registered trademark of Raymarine UK Limited Garmin is a...

Страница 3: ...Strings 16 VI Control from a MFD with CZone Support 25 VII Built in LED Signals 26 VIII Firmware Updates 27 Appendix Troubleshooting 29 Appendix B List of Sound Signals 31 Appendix C List of External...

Страница 4: ...larm and LED flashing sequence Channels and corresponding sound alarms can be turned ON or OFF from other equipment including our smart sensors or from the screen of a modern chart plotter Press the c...

Страница 5: ...ost of equipment installation and configuration neither shipping the defective Device to the manufacturer 5 Responsibility of the manufacturer in case of any damage as a consequence of Device operatio...

Страница 6: ...ls containing an R in the suffix of the model name are equipped with NMEA 2000 connectors and are compatible with Raymarine SeaTalk NG Models containing N in the suffix are equipped with NMEA 2000 Mic...

Страница 7: ...o amplifier output 8 Ohm load at 13V 10 W Load Equivalency Number 20 LEN Built in current limiting resistor for the external LED 200 Ohm External LED power supply 3 3 V Operating temperature range 40...

Страница 8: ...8 II Device overview Figure 2 Functional scheme...

Страница 9: ...Raymarine do not react on MOB message if MOB event with the same MMSI number has being already received but was cancelled earlier Unlike a VHF distress button or activation of EPIRB the signal is not...

Страница 10: ...erature pressure and humidity sensors from Yacht Devices can be set up to turn target digital switching equipment channels ON or OFF when the measured value is too high or too low For example the Digi...

Страница 11: ...lashing sequence for each event using YD LINK command see the Section V To disable or enable the event use YD EVENT command If different events occur at the same time event with lowest number will hav...

Страница 12: ...12 III Device Installation and Connection to NMEA 2000 Figure 3 Device connection...

Страница 13: ...stallation requirements SeaTalk NG Reference Manual 81300 1 for Raymarine networks Technical Reference for Garmin NMEA 2000 Products 190 00891 00 for Garmin networks Note that Device is powered from t...

Страница 14: ...n Figure 4 It is mandatory to crimp contacts soldering is optional Soldering joints must be protected from the environment with paint or lacquer 3 Connection of the sound speaker Device has a built in...

Страница 15: ...programming or wait until the Device enters volume programming after that LED signal In mode programming external LED will continuously flash depending on the current mode 1 short flash MOB button mod...

Страница 16: ...o leave notes or contact information This can be done with professional PC software with a hardware gateway to NMEA 2000 network and it may be supported by some models of chart plotters Please refer t...

Страница 17: ...so allows you to modify the NMEA 2000 device instance by entering a value in the dedicated field After entering the Device Instance value Figure 1 Address Claim settings group click the Update button...

Страница 18: ...specific format mono 16 bit PCM WAV files with sample rate of 22050 Hz and length from 0 1 to 13 seconds from 4 to 688 kBytes Yes the slot size is limited and you will not able to upload your favouri...

Страница 19: ...19 Figure 6 Audio files uploading Full list of commands is given in Table 1 Parameters in square brackets can be omitted to get the current setting value from the Device...

Страница 20: ...ort in milliseconds Values from 50 to 60 000 1 minute are allowed OFF or 0 disables PGN transmission Commands available in all modes YD MODE MOB DS ENGINE YD MODE MOB Set operation mode Device will be...

Страница 21: ...pecified number This setting is ignored in the MOB mode YD INTERVAL 1 28 0 6000 0 YD INTERVAL 1 0 5 YD INTERVAL 3 60 Set interval in seconds second parameter between sound playbacks for specified even...

Страница 22: ...ures required to control loads from chart plotters with CZone support See Section VI for details Table 1 continued YD LIST mmsi YD LIST 338064000 338064001 338064002 YD LIST CLEAR Set list of MMSI num...

Страница 23: ...ory default setting is OFF YD TR_TEMP OFF 0 600 0 600 YD TR_TEMP 200 1 YD TR_TEMP OFF The same as above but for transmission oil temperature turns on event 6 Transmission Over Temperature YD RPM OFF 0...

Страница 24: ...0 YD OIL_PRES OFF Turn ON event 9 Low Oil Pressure when the engine oil pressure is below value specified in the first parameter during specified number of seconds second parameter 0 turns the event O...

Страница 25: ...ymarine MFDs 4 Import the configuration file to the MFD usually from microSD card The only exception is Furuno chart plotters They support uploading of configuration file over NMEA 2000 network only T...

Страница 26: ...o get an NMEA 2000 address it will constantly flash RED one second flash with one second intervals 1 Signals in MOB button mode Device flashes once in two seconds RED no GPS data received GREEN GPS po...

Страница 27: ...py YDAB01 BIN file to the disk README TXT file inside archive can contain important information regarding the update 1 Click NMEA 2000 Devices item in View menu 2 Click Refresh button see Figure 7 at...

Страница 28: ...28 Figure 7 Firmware update of Alarm Button YDAB 01...

Страница 29: ...000 devices on the plotter 1 Loose connection in the data circuit Treat Device connector with a spray for cleaning electrical contacts Plug Device into another connector 2 NMEA 2000 physical layer iss...

Страница 30: ...n sync with NMEA 2000 digital switching equipment in digital switching mode 1 Wrong bank Check that NMEA 2000 digital switching equipment has the same bank Reconfigure Device with YD BANK command see...

Страница 31: ...cy horn sounds 6 Sequence of two chimes low to high frequency 7 Sonar ping 8 Old telephone 9 High frequency beeper 10 Whistle 11 Sequence of two bell rings 12 Mechanical alarm clock 13 Engine order te...

Страница 32: ...t 21 Emergency vehicle siren slow 22 Emergency vehicle siren high to low frequency 23 Square wave 2500 Hz 24 Emergency vehicle horn alternating two tones 25 High frequency bell 26 Low frequency buzz 1...

Страница 33: ...ms ON 150 ms OFF 100ms ON 1 s OFF 6 Three short flashes followed by long delay 100 ms ON 150 ms OFF 100ms ON 150 ms OFF 100ms ON 1 s OFF 7 One long flash followed by long delay 500 ms ON 1 s OFF 8 Tw...

Страница 34: ...5 s OFF 24 One short flash followed by extremely long delay 100 ms ON 7 s OFF 25 One short flash followed by one long flash 100 ms ON 200 ms OFF 400 ms ON 200 ms OFF 26 Two short flashes followed by t...

Страница 35: ...n 8 Low Fuel Level 23 Maintenance Needed 24 Low System Voltage 11 Engine Communication Error 22 Low Coolant Level 12 Sub or Secondary Throttle 25 Water Flow 13 Neutral Start Protection 26 Water in Fue...

Страница 36: ...Group Function Yes Yes PGN 126464 PGN List Rx Tx Yes PGN 126993 Heartbeat Yes See Note 3 PGN 126996 Product Information Yes PGN 126998 Configuration Information Yes PGN 127233 Man Overboard Notificati...

Страница 37: ...ching DS or engine alarm modes NMEA 2000 device class function is 120 Display 140 Alarm Enunciator Note 2 Periodic message with 2 000 ms default interval can be changed in settings see Section V Note...

Страница 38: ......

Отзывы: