— 22 —
String format
Examples
Description
YD:BANK [0..252]
YD:BANK 0
Set the DS bank number, factory setting 0.
YD:OFF <1..28>
YD:ON <1..28>
YD:TOGGLE <1..28>
YD:OFF 1
YD:ON 2
YD:TOGGLE 2
These commands change specified DS channel
state.
YD:CHANNEL [OFF |
0..28]
YD:CHANNEL 3
Select which channel/event will be activated
when external button is pressed. If 0 or
OFF value is specified, the button will only
deactivate events.
YD:MARETRON [OFF
| ON]
YD:MARETRON OFF
Enable or disable compatibility mode with
Maretron digital switching.
YD:CZONE
[ON|OFF|AUTO]
YD:CZONE ON
YD:CZONE AUTO
YD:CZONE OFF
YD:CZONE
Factory setting: AUTO. Activates features
required to control loads from chart plotters
with CZone support. See Section VI for details.
Table 1 continued
YD:LIST [mmsi] [...]
YD:LIST
338064000
338064001
338064002
YD:LIST CLEAR
Set list of MMSI numbers for incoming MOB
PGNs. Device will react only on messages
containing these numbers. Use command “
YD:LIST CLEAR” to empty this list (when
empty, Device reacts on any MMSI).
YD:MOB_SRC [decimal
PGN number] ON|OFF
YD:MOB_SRC
129038 OFF
YD:MOB_SRC
129802 ON
Enable or disable reaction on incoming MOB
PGNs 129038, 129802 or 127233 (by default
all enabled).
Digital switching (DS) mode commands
YD:ALARM <event
number> [NONE |
1..252]|<RESET>
YD:ALARM 38
YD:ALARM RESET
Incoming Raymarine "SeaTalk Alarm" PGN
65288 processing rules. First parameter —
event number (1–28), second — SeaTalk
Alarm ID (1–252). By default all SeaTalk
alarms disabled.
Содержание YDAB-01
Страница 1: ...User Manual Alarm Button YDAB 01 also covers models YDAB 01N YDAB 01R Firmware version 1 08 2022...
Страница 8: ...8 II Device overview Figure 2 Functional scheme...
Страница 12: ...12 III Device Installation and Connection to NMEA 2000 Figure 3 Device connection...
Страница 28: ...28 Figure 7 Firmware update of Alarm Button YDAB 01...
Страница 38: ......