background image

— 9 —

Device can function in one of three modes: MOB button, digital switching alarm unit or engine alarm unit. 

1.  MOB button mode

This mode is factory default. Press connected button for two seconds (button hold time can be changed in 

settings) and Device will start sending NMEA 2000 MOB messages (PGNs 129038, 129802 and 127233), 

using current GPS position data received from NMEA 2000 network. Multifunction displays, chartplotters 

or navigational software (Expedition, OpenCPN) will place MOB mark on the chart, most of the displays 

also will show popup MOB warning. In addition to that, Device will play a sound alarm (Sound 1, or custom 

sound, linked with Event 1) and the external LED will start flashing, confirming that MOB alert is activated. 

Press the button again to cancel MOB alarm and stop sending MOB PGNs.
For the MOB mark, Device uses MMSI number 972777XXX, where XXX is an incremental number from 

000 to 999. This allows to set the mark next time when the previous MOB alert from the Device has been 

cancelled  or  suppressed  by  the  MFD  user.  Incremetation  is  used,  because  some  plotters  (for  example, 

Raymarine) do not react on MOB message, if MOB event with the same MMSI number has being already 

received but was cancelled earlier.
Unlike a VHF distress button or activation of EPIRB, the signal is not sent out from the boat. The main 

purposes of the Alarm Button are to wake up your crew with a sound alert and place the MOB position on 

all chart plotters on board. Device is essential for you if you have no chart plotter near the helm, or if your 

MFD has no hardware MOB button and you need it to comply with racing rules.
Device can be activated not only by pressing button, but also by MOB PGNs received from a NMEA 2000 

AIS unit or chartplotter: PGN 127233 — "Man Overboard Notification (MOB)", PGN 129038 — "AIS Class 

A Position Report" (with data field "Navigational Status" = 14, SART ACTIVE), PGN 129802 — "AIS Safety 

Related Broadcast Message" (with data field "Safety Related Text" = "SART_ACTIVE" or "MOB_ACTIVE" 

or  "EPIRB_ACTIVE")  and  Raymarine  proprietary  PGN  65288  "SeaTalk  Alarm"  (with  "alarm  ID"  =  38, 

MOB). 

Reaction on each PGN (127233|129038|129802) can be switched ON/OFF via YD:MOB_SRC command 

(see Section V).

You can force device to react only to MOB PGNs with a specific MMSI numbers, included in a custom list 

of your own EPIRB/MOB devices via YD:LIST command (see Section V). By default, device will react to 

any MMSI.

Содержание YDAB-01

Страница 1: ...User Manual Alarm Button YDAB 01 also covers models YDAB 01N YDAB 01R Firmware version 1 08 2022...

Страница 2: ...B 01 002 May 24 2022 Web http www yachtd com NMEA 2000 is a registered trademark of the National Marine Electronics Association SeaTalk NG is a registered trademark of Raymarine UK Limited Garmin is a...

Страница 3: ...Strings 16 VI Control from a MFD with CZone Support 25 VII Built in LED Signals 26 VIII Firmware Updates 27 Appendix Troubleshooting 29 Appendix B List of Sound Signals 31 Appendix C List of External...

Страница 4: ...larm and LED flashing sequence Channels and corresponding sound alarms can be turned ON or OFF from other equipment including our smart sensors or from the screen of a modern chart plotter Press the c...

Страница 5: ...ost of equipment installation and configuration neither shipping the defective Device to the manufacturer 5 Responsibility of the manufacturer in case of any damage as a consequence of Device operatio...

Страница 6: ...ls containing an R in the suffix of the model name are equipped with NMEA 2000 connectors and are compatible with Raymarine SeaTalk NG Models containing N in the suffix are equipped with NMEA 2000 Mic...

Страница 7: ...o amplifier output 8 Ohm load at 13V 10 W Load Equivalency Number 20 LEN Built in current limiting resistor for the external LED 200 Ohm External LED power supply 3 3 V Operating temperature range 40...

Страница 8: ...8 II Device overview Figure 2 Functional scheme...

Страница 9: ...Raymarine do not react on MOB message if MOB event with the same MMSI number has being already received but was cancelled earlier Unlike a VHF distress button or activation of EPIRB the signal is not...

Страница 10: ...erature pressure and humidity sensors from Yacht Devices can be set up to turn target digital switching equipment channels ON or OFF when the measured value is too high or too low For example the Digi...

Страница 11: ...lashing sequence for each event using YD LINK command see the Section V To disable or enable the event use YD EVENT command If different events occur at the same time event with lowest number will hav...

Страница 12: ...12 III Device Installation and Connection to NMEA 2000 Figure 3 Device connection...

Страница 13: ...stallation requirements SeaTalk NG Reference Manual 81300 1 for Raymarine networks Technical Reference for Garmin NMEA 2000 Products 190 00891 00 for Garmin networks Note that Device is powered from t...

Страница 14: ...n Figure 4 It is mandatory to crimp contacts soldering is optional Soldering joints must be protected from the environment with paint or lacquer 3 Connection of the sound speaker Device has a built in...

Страница 15: ...programming or wait until the Device enters volume programming after that LED signal In mode programming external LED will continuously flash depending on the current mode 1 short flash MOB button mod...

Страница 16: ...o leave notes or contact information This can be done with professional PC software with a hardware gateway to NMEA 2000 network and it may be supported by some models of chart plotters Please refer t...

Страница 17: ...so allows you to modify the NMEA 2000 device instance by entering a value in the dedicated field After entering the Device Instance value Figure 1 Address Claim settings group click the Update button...

Страница 18: ...specific format mono 16 bit PCM WAV files with sample rate of 22050 Hz and length from 0 1 to 13 seconds from 4 to 688 kBytes Yes the slot size is limited and you will not able to upload your favouri...

Страница 19: ...19 Figure 6 Audio files uploading Full list of commands is given in Table 1 Parameters in square brackets can be omitted to get the current setting value from the Device...

Страница 20: ...ort in milliseconds Values from 50 to 60 000 1 minute are allowed OFF or 0 disables PGN transmission Commands available in all modes YD MODE MOB DS ENGINE YD MODE MOB Set operation mode Device will be...

Страница 21: ...pecified number This setting is ignored in the MOB mode YD INTERVAL 1 28 0 6000 0 YD INTERVAL 1 0 5 YD INTERVAL 3 60 Set interval in seconds second parameter between sound playbacks for specified even...

Страница 22: ...ures required to control loads from chart plotters with CZone support See Section VI for details Table 1 continued YD LIST mmsi YD LIST 338064000 338064001 338064002 YD LIST CLEAR Set list of MMSI num...

Страница 23: ...ory default setting is OFF YD TR_TEMP OFF 0 600 0 600 YD TR_TEMP 200 1 YD TR_TEMP OFF The same as above but for transmission oil temperature turns on event 6 Transmission Over Temperature YD RPM OFF 0...

Страница 24: ...0 YD OIL_PRES OFF Turn ON event 9 Low Oil Pressure when the engine oil pressure is below value specified in the first parameter during specified number of seconds second parameter 0 turns the event O...

Страница 25: ...ymarine MFDs 4 Import the configuration file to the MFD usually from microSD card The only exception is Furuno chart plotters They support uploading of configuration file over NMEA 2000 network only T...

Страница 26: ...o get an NMEA 2000 address it will constantly flash RED one second flash with one second intervals 1 Signals in MOB button mode Device flashes once in two seconds RED no GPS data received GREEN GPS po...

Страница 27: ...py YDAB01 BIN file to the disk README TXT file inside archive can contain important information regarding the update 1 Click NMEA 2000 Devices item in View menu 2 Click Refresh button see Figure 7 at...

Страница 28: ...28 Figure 7 Firmware update of Alarm Button YDAB 01...

Страница 29: ...000 devices on the plotter 1 Loose connection in the data circuit Treat Device connector with a spray for cleaning electrical contacts Plug Device into another connector 2 NMEA 2000 physical layer iss...

Страница 30: ...n sync with NMEA 2000 digital switching equipment in digital switching mode 1 Wrong bank Check that NMEA 2000 digital switching equipment has the same bank Reconfigure Device with YD BANK command see...

Страница 31: ...cy horn sounds 6 Sequence of two chimes low to high frequency 7 Sonar ping 8 Old telephone 9 High frequency beeper 10 Whistle 11 Sequence of two bell rings 12 Mechanical alarm clock 13 Engine order te...

Страница 32: ...t 21 Emergency vehicle siren slow 22 Emergency vehicle siren high to low frequency 23 Square wave 2500 Hz 24 Emergency vehicle horn alternating two tones 25 High frequency bell 26 Low frequency buzz 1...

Страница 33: ...ms ON 150 ms OFF 100ms ON 1 s OFF 6 Three short flashes followed by long delay 100 ms ON 150 ms OFF 100ms ON 150 ms OFF 100ms ON 1 s OFF 7 One long flash followed by long delay 500 ms ON 1 s OFF 8 Tw...

Страница 34: ...5 s OFF 24 One short flash followed by extremely long delay 100 ms ON 7 s OFF 25 One short flash followed by one long flash 100 ms ON 200 ms OFF 400 ms ON 200 ms OFF 26 Two short flashes followed by t...

Страница 35: ...n 8 Low Fuel Level 23 Maintenance Needed 24 Low System Voltage 11 Engine Communication Error 22 Low Coolant Level 12 Sub or Secondary Throttle 25 Water Flow 13 Neutral Start Protection 26 Water in Fue...

Страница 36: ...Group Function Yes Yes PGN 126464 PGN List Rx Tx Yes PGN 126993 Heartbeat Yes See Note 3 PGN 126996 Product Information Yes PGN 126998 Configuration Information Yes PGN 127233 Man Overboard Notificati...

Страница 37: ...ching DS or engine alarm modes NMEA 2000 device class function is 120 Display 140 Alarm Enunciator Note 2 Periodic message with 2 000 ms default interval can be changed in settings see Section V Note...

Страница 38: ......