Installation instructions

 

Safety brake 
FG 40-31,75 Ex

 

For use in potentially explosive atmospheres (Ex) 
 

Type: 10005266 00001

 

 

 

Pos: 2 /BA_Module/BA_Seitenumbruch @ 0\mod_1190719383361_0.docx @ 550 @  @ 1 

 

 

 

-en- 

Version: 06.03.2020

Содержание FG 40-31,75 Ex

Страница 1: ..._Deckblatt_ATEX_00000_M002 21 mod_1479899122976_28 docx 1020557 1 Installation instructions Safety brake FG 40 31 75 Ex For use in potentially explosive atmospheres Ex Type 10005266 00001 Pos 2 BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 en Version 06 03 2020 ...

Страница 2: ... 120 02_Leerseite 02_Leerseite_00000_M001 10 mod_1363019735654_28 docx 785354 1 GfA ELEKTROMATEN GmbH Co KG Wiesenstraße 81 40549 Düsseldorf www gfa elektromaten de info gfa elektromaten de Pos 2 BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 3: ...rical installation 11 7 Safety brake activation 12 8 Repairs 13 9 Completion of initial operation inspection 14 10 Declaration of conformity 15 11 Declaration of conformity 16 12 Konformitätserklärung Zubehör 17 Pos 2 BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 Symbols Warning Potential injury or danger to life Warning Danger to life from electric current Note Important information...

Страница 4: ... or non observance of the information in the manual Modifications are only permitted with the agreement of the manufacturer Otherwise the Manufacturer s Declaration shall be rendered null and void Safety information Installation and commissioning are to be carried out by skilled personnel only Only trained electrical craftsmen are permitted to work on electrical equipment They must assess the task...

Страница 5: ...ring load Fmax 3000 N Keyway width 8 mm Keyway height 33 3 mm Degree of protection IP 65 Admissible temperature range 20 40 C 3 Technical data of limit switch switch for manual operation Type 07 2511 113001 Manufacturer Bartec Explosion protection II 2G Ex d IIC T6 II 2D Ex tD A21 IP 66 T80 C Test certificate G PTB 00 ATEX 1093 D IBExU01 ATEX 1007 Supply voltage 400 V Temperature range 20 40 C Deg...

Страница 6: ...r 4 Floating foot 5 Cover aluminium Fmax Permissible bearing see technical data In normal operation the safety brake functions similar to pedestal bearings The safety brake is tripped as soon as the maximum operating speed in DOWN direction is exceeded This results in the following reactions The shaft is blocked in DOWN direction The safety switch is actuated to interrupt the control current Relea...

Страница 7: ...ximum locking torque observe technical data Connection elements Use self locking connection elements with a minimum strength of 800 N mm2 8 8 Use a screw that precisely fits the hole Use adequately dimensioned washers for elongated holes BAGAB00002_Z002 BAGAB00003_Z002 3 1 Permissible mounting positions BAGAC09001_Z001 Ab Down Ab Down Ab Down Ab Down ...

Страница 8: ...8 Mounting 2 elongated holes are provided for mounting BAGAD09001_Z001 ...

Страница 9: ...her defined The facility or door manufacturer s specifications must also be observed Warning Injury or danger to life possible Use a lifting device with sufficient load carrying capacity for installation tasks Completely grease the door shaft BAGAE01001_Z003 Mount the key BAGAE03002_Z001 ...

Страница 10: ...ments M12 with a torque of 75 Nm Install all further connection elements according to the specifications of the door or facility manufacturer 75 Nm 8 8 8 8 BAGAE09002_Z001 Note If the safety brake has been tripped during installation follow the procedure described under Safety brake activation ...

Страница 11: ...ty switch to the EMERGENCY STOP input of the door control When the safety brake is activated the electrical circuit is interrupted and the electrical operation of the gate is no longer possible Carrying out the electrical installation Cable of the safety brake s safety switch Connection of the cable to the EMERGENCY STOP input of the door control Warning Injury or danger to life possible The safet...

Страница 12: ...unger Warning De energise the facility and secure against unintended switching on Secure door load against falling Rectify the cause of tripping drive unit chain etc Any time the safety brake has been tripped it must be disassembled and checked If the control pointer is damaged the safety brake must be replaced Unscrew 3xT20 cover aluminium and assess control pointer Control pointer broken Ⓐ Repla...

Страница 13: ... brake activation Ⓒ the safety brake can be repaired Rotate hollow shaft in OPEN direction by approx 90 90 Press the red plunger back into the housing The safety brake is ready for operation again Pos 2 BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 14: ... plug connections for correct seating and electrical contact Mounting position On the basis of the OBEN TOP and AB DOWN markings and by checking Maintenance inspection The safety brake requires no maintenance The safety brake is type approved Checking for correct functioning is not required and inadmissible once the safety brake is installed Entire safety brake Note Have a specialist check the saf...

Страница 15: ...ove directives and is only intended for installation in a door system Safety brake FG 40 31 75 Ex Part no 10005266 00001 Authorised representative to compile the technical documents is the undersigned Düsseldorf 10 08 2018 Stephan Kleine CEO Signature Standards applied EN 12604 2017 Industrial commercial and garage doors and gates Mechanical aspects Requirements EN 12605 2000 Industrial commercial...

Страница 16: ... our sole responsibility that the following module complies with the above directive and that no new hazards arise from assembly The assembled modul are only intended for installation in a door system Safety brake FG 40 31 75 Ex Part no 10005266 00001 Consisting of Safety brake FG 40 31 75 Ex Safety switches 07 2511 Higher level product identification code II 2G c IIB T3 Authorised representative ...

Страница 17: ...ichtungen FG 40 120 10_ Konformitätserklärung_Ex_Baugruppen 09_Konformitätserklärung_Ex_Baugruppen_M001 13 mod_1387288740748_28 docx 825667 1 12 Konformitätserklärung Zubehör Pos 2 BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 18: ...tem Safety brake FG 40 31 75 Ex Part no 10005266 00001 Authorised representative to compile the technical documents is the undersigned Düsseldorf 10 08 2018 Stephan Kleine CEO Signature Identification of the product according to Directive II 2G c IIB T3 Notified body pursuant to Directive TÜV Nord Anlagetechnik GmbH Am TÜV 1 30519 Hannover Deutschland Registration number 8000313442 Standards appli...

Страница 19: ...19 Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 20: ...20 Ende der Liste für Textmarke Inhalt1 ...

Отзывы: