Completion of initial operation / inspection
Check the following components and after that, mount all covers.
Mounting
Check all mounting elements (consoles, screws, retaining rings etc.) for tightness and
impeccable condition.
Electric wiring
Check connection cables and cables for damage or pinches.
Check screw and plug connections for correct seating and electrical contact.
Mounting position
On the basis of the OBEN/TOP and AB/DOWN markings and by checking.
Maintenance/inspection
The safety brake requires no maintenance.
The safety brake is type-approved. Checking for correct functioning is not required and
inadmissible once the safety brake is installed.
Entire safety brake
Note!
Have a specialist check the safety brake once a year.
Shorter inspection interval for frequently used equipment or doors.
Observe the applicable regulations and standards
=== Ende der Liste für Textmarke Inhalt ===
Warning – Injury or danger to life possible!
Do not activate the safety brake without having connected the safety switch!