P12.11
Fan operating mode
0: Start the fan when the motor is running;
after the motor stops, turn off the fan with
a delay of about 1 minute;
1: When the temperature is higher than the
fan action temperature point (P12.12), the
fan will be started immediately; when the
temperature is lower than the fan action
temperature point, the fan will be turned
off after a delay of about 1 minute;
2: Unconditionally force the fan to start;
3: The fan does not work;
1
P12.12
Cooling fan action
temperature point
45
P12.13
Fan detection
P12.14
Bypass relay closed
detection
P12.15
Bypass relay delay time
P12.16
Initial value of power-on
delay timer (seconds)
P12.17
Current sensor configuration
P12.18
Automatic voltage
regulation function selection
P12.19
PWM frequency
2.0-15.0KHZ
8.0KHZ
P12.20
SVPWM mode
0: Three-phase asynchronous motor, 1:
Two-phase asynchronous motor
(single-phase motor, 90 degree phase
difference, no starting capacitor)
0
P13.00
Software version number
P13.01
Hardware version number
P13.02
Manufacturer
P13.03
Year of manufacture & week
P13.04
Product ID (Combine year &
week of manufacture to
become UID)
P13.05
Accumulated running time
of the machine (hours)