22
P07.00
1st section frequency setting
0.0-600.0HZ
0.0HZ
P07.01
2st section frequency setting
100.0HZ
P07.02
3st section frequency setting
150.0HZ
P07.03
4st section frequency setting
200.0HZ
P07.04
5st section frequency setting
250.0HZ
P07.05
6st section frequency setting
300.0HZ
P07.06
7st section frequency setting
350.0HZ
P07.07
8st section frequency setting
400.0HZ
P07.08
1st frequency source
selection
0: Operation panel potentiometer given
frequency
(related
parameters:
P03.06~P03.09)
1: Digital operation panel setting
frequency, that is, the frequency value set
by parameter P00.00, directly set by the
operation panel keyboard
2: The x-section frequency P07.00~P07.07
3: External analog quantity 1 (AI1/VI1)
(related parameters: P03.10~P03.13), see
"JP1 short-circuit block configuration
table"
4: reserved
5: Modbus Rs485 given frequency
6: User application given frequency
Other: reserved
0
P07.09
2st frequency source
selection
2
P07.10
3st frequency source
selection
2
P07.11
4st frequency source
selection
2
P07.12
5st frequency source
selection
2
P07.13
6st frequency source
selection
2
P07.14
7st frequency source
selection
2
P07.15
8st frequency source
selection
2
P07.16
Forward jog frequency
0.0-600.0HZ
15.0HZ
P07.17
Reverse jog frequency
15.0HZ
P08.00
Automatic operation mode:
direction of rotation
P08.01
Automatic operation mode:
cycle mode selection
P08.02
Automatic running time
unit: second/minute
P08.03
Automatic operation mode
1st speed operation time
P08.04
Automatic operation mode
2st speed operation time
P08.05
Automatic operation mode
3st speed operation time
P08.06
Automatic operation mode
4st speed operation time
P08.07
Automatic operation mode
5st speed operation time