the motor direction.
7: When REV (X4) is open, FWD (X5)
closes and starts the motor in the forward
direction; when REV (X4) is closed, it is
forbidden to start the motor; when REV
(X4) closes, it stops instantly.
8: Wire cutting left and right limit
commutation mode (X3 function should be
set to "reserved", that is, P00.19=0. Refer
to "wire cutting left and right limit
commutation mode wiring diagram").
When START (X5) is open, stop. When
START is closed, the direction is
determined according to the current state
of the limit switch, and the motor is
started. When START is closed, if the state
of the two limit switches are both open, the
default is to the left Start the motor. During
running to the left, when the left limit
switch (X_LSL, namely X3) is closed
(limit), it changes to running to the right.
During running to the right, when the right
limit switch (X_LSR, namely X4) is closed
(limit), it changes to running to the left. If
the left and right limits are at the same
time, the machine will stop; Note:
Multi-function relay 1
The function (P04.03) is selected as 17
(powered at constant speed, otherwise
power is lost), and P04.05 and P04.06 are
set to realize the wire cutting "switch high
frequency" function.
P00.17
Multi-function input X1
function selection
0: reserved
1: Multi-speed command
5: Used as forward jog input
6: Used as reverse jog input
7: Used as a jog input (REV (X4)
determines the direction)
8: Shutdown instantly when closing action
9: Shut down instantly when disconnected
10: Disconnect, immediately stop with DC
braking (regardless of PV_StopMode
setting)
11: External terminal speed increase
1