![Ya Lang YL600-1.5KW-220V Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/ya-lang/yl600-1-5kw-220v/yl600-1-5kw-220v_manual_3074792012.webp)
12
7. Function description and list
7.1 Function table
:
(YL600)
Inverter parameter table
Parameter
number
name
Setting range and its meaning
Factory default
P00.00
Main frequency
0.0-600.0HZ
50.0HZ
P00.01
Start/stop command source
0
:
Operate the motor by the operation
panel
1
:
The motor is controlled by the external
terminal, and the STOP button on the
operation panel is effective
2
:
The motor is operated by the external
terminal, and the STOP button on the
operation panel is invalid
3
:
Motor controlled by Modbus Rs485
0
P00.02
Reserved
0
P00.03
Motor stop mode
0
:
Decelerate to stop
1
:
Free stop (deceleration time is invalid)
2
:
Immediate DC braking to stop (the
deceleration time is invalid)
0
P00.04
VF curve-maximum output
frequency
1.0-600.0HZ
50.0HZ
P00.05
VF curve-output frequency
at maximum voltage
5.0.0-600.0HZ
50.0HZ
P00.06
VF curve-maximum output
voltage
10.0%-150.0%
100.00%
P00.07
VF curve-intermediate
frequency
1.0-600.0HZ
3.5HZ
P00.08
VF curve-intermediate
voltage
10.0%-100.0%
10%
P00.09
VF curve-minimum output
frequency
0.0-600.0HZ
0.2HZ
P00.10
VF curve-minimum output
voltage
0%-100.0%
1.0%
P00.11
Use analog input 1 to control
multi-speed
0%-100%
100
P00.12
VF curve style selection
0-4
0
P00.13
Parameter
recovery/locking/read and
write
0
:
Allow users to set parameters
1
:
Forbid users to set parameters (locked)
10
:
Restore factory parameters (need to
power off, power on again)
0