Xylem YSI IDS ProOBOD Скачать руководство пользователя страница 12

16

17

A P P E N D I X   A - D O %   C A L I B R A T I O N 
V A L U E S

Pressure

Altitude

Calibration 

value 

Inches Hg

mm Hg

kPA

mbar

Feet

Meters

% Saturation

30.2

767.6

102.3

1023

-276

-84

101

29.92

760

101.3

1013

0

0

100

29.62

752.4

100.3

1003

278

85

99

29.32

744.8

99.3

993

558

170

98

29.02

737.2

98.3

983

841

256

97

28.72

729.6

97.3

973

1126

343

96

28.43

722

96.3

963

1413

431

95

28.13

714.4

95.2

952

1703

519

94

27.83

706.8

94.2

942

1995

608

93

27.53

699.2

93.2

932

2290

698

92

27.23

691.6

92.2

922

2587

789

91

26.93

684

91.2

912

2887

880

90

26.63

676.4

90.2

902

3190

972

89

26.33

668.8

89.2

892

3496

1066

88

26.03

661.2

88.1

881

3804

1106

87

25.73

653.6

87.2

871

4115

1254

86

25.43

646

86.1

861

4430

1350

85

25.13

638.4

85.1

851

4747

1447

84

24.84

630.8

84.1

841

5067

1544

83

24.54

623.2

83.1

831

5391

1643

82

24.24

615.6

82.1

821

5717

1743

81

23.94

608

81.06

811

6047

1843

80

23.64

600.4

80.05

800

6381

1945

79

23.34

592.8

79.03

790

6717

2047

78

23.04

585.2

78.02

780

7058

2151

77

22.74

577.6

77.01

770

7401

2256

76

22.44

570.0

75.99

760

7749

2362

75

Pressure

Altitude

Calibration 

value 

Inches Hg

mm Hg

kPA

mbar

Feet

Meters

% Saturation

22.14

562.4

74.98

749

8100

2469

74

21.84

554.8

73.97

739

8455

2577

73

21.54

547.2

72.95

729

8815

2687

72

21.26

539.6

71.94

720

9178

2797

71

20.94

532

70.93

709

9545

2909

70

20.64

524

69.92

699

9917

3023

69

20.35

517

68.91

689

10293 3137

68

20.05

509

67.9

679

10673 3371

67

19.75

502

66.89

669

11058 3371

66

Содержание YSI IDS ProOBOD

Страница 1: ...USER MANUAL Document 626471 ProOBOD IDS ProOBOD ...

Страница 2: ...Dissolved Oxygen 4 Temperature 5 Taking Measurements 5 Maintenance and Storage 5 Updating Instrument and Probe Firmware 6 Sensor Maintenance Dissolved Oxygen 6 Sensor Maintenance Temperature 8 Sensor Storage 9 Troubleshooting 9 Dissolved Oxygen Readings 9 Error Status messages 11 Probe Specifications 11 Accessories Parts List 12 Declaration of Conformity 13 Recycling 14 Contact Information 14 Orde...

Страница 3: ...ervice Center selected by YSI Repair or replacement will be made and the product returned transportation prepaid Repaired or replaced products are warranted for the balance of the original warranty period or at least 90 days from date of repair or replacement LIMITATION OF WARRANTY This Warranty does not apply to any YSI product damage or failure caused by 1 Failure to install operate or use the p...

Страница 4: ...nt It fits in standard USA BOD bottles standard Japanese BOD bottles and many other international BOD bottles A funnel adapter for fitting in standard UK BOD bottles and a switching power supply with 3 international outlet adapters are also included IDS ProOBOD YSI item number 626500 This probe works with a MultiLab IDS instrument It fits in standard USA BOD bottles standard Japanese BOD bottles a...

Страница 5: ... contact YSI Customer Service at 800 897 4151 1 937 767 7241 or environmental ysi com or contact the authorized YSI distributor where the instrument was purchased Remove the OBOD probe cable assembly from the shipping container and locate the instruction sheet that is included This instruction sheet is important because it contains the calibration coefficients for your sensor cap A new probe cable...

Страница 6: ...ift than traditional electrochemical sensors This increased stability means that the instrument may hold its calibration for many months However for the highest data accuracy YSI recommends verifying the instrument s calibration on a daily basis To verify the instrument s calibration place the sensor in a water saturated air environment BOD bottle with 40 ml of water and check to see that the DO m...

Страница 7: ...section of this manual for instructions on how to determine if the sensor cap needs replaced The replacement OBOD sensor cap is shipped in a humidified container and the package should not be opened until the cap is needed for use Once the sensor cap has been installed on the OBOD probe as described in this section it is important to keep the sensor in a 100 humid environment Therefore the OBOD se...

Страница 8: ...ature portion of the sensor free of build up Other than that the sensor requires no maintenance A soft bristle brush can be used to scrub the temperature sensor if needed While cleaning be sure to only scrub the temperature sensor and not the sensor cap The sensor cap will be damaged if cleaned with anything abrasive Sensor Storage Short term Storage When the OBOD is not in use it must be stored i...

Страница 9: ... carefully remove the o ring and contact YSI Technical Support to obtain a new o ring and or gasket Avoid using tools to remove the o ring as damage to the sealing surfaces could result Before reinstalling the sensor cap make sure that the cavity is completely clean and dry before proceeding with the installation If water is found dry the cavity with lens tissue Finally clean and dry the clear opt...

Страница 10: ...ms to Australian and New Zealand EMC requirements for C Tick and RCM marks It conforms to unintentional radiator requirements under FCC Part 15 and ICES 003 Class B Manufacturer YSI Incorporated 1725 Brannum Lane Yellow Springs OH 45387 USA Product Name Professional ODO Water Quality Instrument and Professional OBOD probe Model Numbers Instrument Accessory ProODO 626281 ProComm Saddle manufactured...

Страница 11: ...8 technical support Email environmental ysi com Mail YSI Incorporated 1725 Brannum Lane Yellow Springs OH 45387 USA Internet ysi com When placing an order please have the following available 1 YSI account number if available 2 Name and phone number 3 Purchase Order or Credit Card 4 Model Number or brief description 5 Billing and shipping addresses 6 Quantity Service Information YSI has authorized ...

Страница 12: ...106 87 25 73 653 6 87 2 871 4115 1254 86 25 43 646 86 1 861 4430 1350 85 25 13 638 4 85 1 851 4747 1447 84 24 84 630 8 84 1 841 5067 1544 83 24 54 623 2 83 1 831 5391 1643 82 24 24 615 6 82 1 821 5717 1743 81 23 94 608 81 06 811 6047 1843 80 23 64 600 4 80 05 800 6381 1945 79 23 34 592 8 79 03 790 6717 2047 78 23 04 585 2 78 02 780 7058 2151 77 22 74 577 6 77 01 770 7401 2256 76 22 44 570 0 75 99 ...

Страница 13: ...Item 626471 Rev C Drawing 626471 April 2013 2013 YSI Incorporated ...

Отзывы: