Xylem YSI IDS ProOBOD Скачать руководство пользователя страница 10

12

13

Temperature

Range

-5 to 50°C

Accuracy

± 0.2°C

Resolution

0.1°C

 

A C C E S S O R I E S   /   P A R T S   L I S T

Part Number

Description

626281

ProODO Instrument

626400

ProOBOD USA/Japan BOD lab probe* 
for use with ProODO instrument

626401

ProOBOD International BOD lab probe* 
for use with ProODO instrument

626500

IDS ProOBOD* for use with 
MultiLab instruments

626482

Replacement sensor cap for ProOBOD 
and IDS ProOBOD lab probe

626600

6260 power supply for use with 626400 
ProOBOD USA/Japan BOD probe

626601

6261 power supply for use with 626401 
ProOBOD International probe

626415

Stir Shaft

626473

k Funnel, for use in Uk standard BOD bottles

*All probe/cable assemblies include a temperature and dissolved 
oxygen sensor.  
 

D E C L A R A T I O N   O F   C O N F O R M I T Y

We declare under our sole responsibility that the listed product conforms 
to the requirements for the listed European Council Directive(s) and carries 
the CE mark accordingly. It conforms to Australian and New Zealand EMC 
requirements for C-Tick and RCM marks. It conforms to unintentional radiator 
requirements under FCC Part 15 and ICES-003 Class B.

Manufacturer:

YSI Incorporated
1725 Brannum Lane
Yellow Springs, Oh 45387
USA

Product Name:

Professional ODO Water Quality Instrument 
and Professional OBOD probe

Model Numbers
Instrument/Accessory:

ProODO (626281) / ProComm Saddle 
manufactured after September 1, 2010 
(Lot code 10J and later) (605404)

Probe/Cable 
Assemblies:

ProOBOD (626400, 626401)
IDS ProOBOD (626500)

Conforms to the following:
Directives:

EMC 2004/108/EC
RohS 2011/65/EU
WEEE 2002/96/EC

Harmonized 
Standards:

• EN61326-1:2006.
• EN61326-2-3:2006.
• EN61000-3-2:2006.
• EN61000-3-3:2008.
• CAN/CSA-CEI/IEC CISPR 22:02

Supplementary 
Information:

All performance met the continuous 
unmonitored operation criteria as follows:
EN61000-4-2:2009
EN61000-4-3: 2006
EN61000-4-4:2004
EN61000-4-5: 2006
EN61000-4-6: 2009
EN61000-4-11:2004

Authorized EU 
Representative

YSI hydrodata Ltd
2 Focal Point, Lacerta Court, Works Road
Letchworth, hertfordshire, SG6 IFJ Uk

Signed:  Lisa M. Abel          

 

 

         Date:  24 April 2013

Title:  Director of Quality

Содержание YSI IDS ProOBOD

Страница 1: ...USER MANUAL Document 626471 ProOBOD IDS ProOBOD ...

Страница 2: ...Dissolved Oxygen 4 Temperature 5 Taking Measurements 5 Maintenance and Storage 5 Updating Instrument and Probe Firmware 6 Sensor Maintenance Dissolved Oxygen 6 Sensor Maintenance Temperature 8 Sensor Storage 9 Troubleshooting 9 Dissolved Oxygen Readings 9 Error Status messages 11 Probe Specifications 11 Accessories Parts List 12 Declaration of Conformity 13 Recycling 14 Contact Information 14 Orde...

Страница 3: ...ervice Center selected by YSI Repair or replacement will be made and the product returned transportation prepaid Repaired or replaced products are warranted for the balance of the original warranty period or at least 90 days from date of repair or replacement LIMITATION OF WARRANTY This Warranty does not apply to any YSI product damage or failure caused by 1 Failure to install operate or use the p...

Страница 4: ...nt It fits in standard USA BOD bottles standard Japanese BOD bottles and many other international BOD bottles A funnel adapter for fitting in standard UK BOD bottles and a switching power supply with 3 international outlet adapters are also included IDS ProOBOD YSI item number 626500 This probe works with a MultiLab IDS instrument It fits in standard USA BOD bottles standard Japanese BOD bottles a...

Страница 5: ... contact YSI Customer Service at 800 897 4151 1 937 767 7241 or environmental ysi com or contact the authorized YSI distributor where the instrument was purchased Remove the OBOD probe cable assembly from the shipping container and locate the instruction sheet that is included This instruction sheet is important because it contains the calibration coefficients for your sensor cap A new probe cable...

Страница 6: ...ift than traditional electrochemical sensors This increased stability means that the instrument may hold its calibration for many months However for the highest data accuracy YSI recommends verifying the instrument s calibration on a daily basis To verify the instrument s calibration place the sensor in a water saturated air environment BOD bottle with 40 ml of water and check to see that the DO m...

Страница 7: ...section of this manual for instructions on how to determine if the sensor cap needs replaced The replacement OBOD sensor cap is shipped in a humidified container and the package should not be opened until the cap is needed for use Once the sensor cap has been installed on the OBOD probe as described in this section it is important to keep the sensor in a 100 humid environment Therefore the OBOD se...

Страница 8: ...ature portion of the sensor free of build up Other than that the sensor requires no maintenance A soft bristle brush can be used to scrub the temperature sensor if needed While cleaning be sure to only scrub the temperature sensor and not the sensor cap The sensor cap will be damaged if cleaned with anything abrasive Sensor Storage Short term Storage When the OBOD is not in use it must be stored i...

Страница 9: ... carefully remove the o ring and contact YSI Technical Support to obtain a new o ring and or gasket Avoid using tools to remove the o ring as damage to the sealing surfaces could result Before reinstalling the sensor cap make sure that the cavity is completely clean and dry before proceeding with the installation If water is found dry the cavity with lens tissue Finally clean and dry the clear opt...

Страница 10: ...ms to Australian and New Zealand EMC requirements for C Tick and RCM marks It conforms to unintentional radiator requirements under FCC Part 15 and ICES 003 Class B Manufacturer YSI Incorporated 1725 Brannum Lane Yellow Springs OH 45387 USA Product Name Professional ODO Water Quality Instrument and Professional OBOD probe Model Numbers Instrument Accessory ProODO 626281 ProComm Saddle manufactured...

Страница 11: ...8 technical support Email environmental ysi com Mail YSI Incorporated 1725 Brannum Lane Yellow Springs OH 45387 USA Internet ysi com When placing an order please have the following available 1 YSI account number if available 2 Name and phone number 3 Purchase Order or Credit Card 4 Model Number or brief description 5 Billing and shipping addresses 6 Quantity Service Information YSI has authorized ...

Страница 12: ...106 87 25 73 653 6 87 2 871 4115 1254 86 25 43 646 86 1 861 4430 1350 85 25 13 638 4 85 1 851 4747 1447 84 24 84 630 8 84 1 841 5067 1544 83 24 54 623 2 83 1 831 5391 1643 82 24 24 615 6 82 1 821 5717 1743 81 23 94 608 81 06 811 6047 1843 80 23 64 600 4 80 05 800 6381 1945 79 23 34 592 8 79 03 790 6717 2047 78 23 04 585 2 78 02 780 7058 2151 77 22 74 577 6 77 01 770 7401 2256 76 22 44 570 0 75 99 ...

Страница 13: ...Item 626471 Rev C Drawing 626471 April 2013 2013 YSI Incorporated ...

Отзывы: