Heat / Cooling meter integrator PolluTherm 
Installation and operation instructions 
 

 

M H 6111 INT PolluTherm, page 9 

 

Checksum 

 

High-resolution energy 
display 

 

High-resolution volume 

 

Return to selection menu 
(push for 2 seconds) 

 

8.5 Control menu for tariff purposes (example) 

 
Each display item is marked with the letters „Ctrl“. 
The settings for the tariff functions can be 
controlled here. 
 

 

Preset averaging interval 
for flow rate and power 

 

Power in current 
averaging interval 

 

Flow rate in current 
averaging interval 

 

Set tariff 1 
(if activated) * 

 

Switchover point for 
supply temperature cool 
metering 
(if activated) * 

 

Switchover point for 
negative temperature 
difference cool metering 
(if activated) * 

 

Correction factor for water-
antifreeze mixtures (if 
activated) 

 

Return to selection menu 
(push for 2 seconds) 

 

8.6 Parameter menu (example) 

 
Each display item is marked with the tool symbol. 
This menu is protected by password. The 
password corresponds to the last three digits of 
the eight-digit serial number on the meter housing. 

At the beginning “000“ appears. Push the key for 
approx. 2 seconds; the zero on the left side starts 
flashing. By continuously pushing the key the 
value of the flashing digit can be changed. As 
soon as the desired value is obtained release the 
key. A short key stroke confirms the set value and 
switches to the next position. Proceed as 
mentioned in the previous step. After setting the 
last digit the level is activated. 
The desired positions can now be selected by 
short keystroke; adjusting the values is similar to 
the password entry procedure. 
Default values are read out with the setting "OnE 
COMPA". The setting  "OnE, OnE Plus, ALL" 
additionally activates the read out of further 
information. 

 

Password scan 

 

Setting 
primary M-Bus address 

 

Setting 
secondary 
M-Bus address 

 

Setting 
customer’s refernce 
number 

 

Setting 
averaging interval for flow 
rate and power 

 

Setting data transmission 
mode (One, All, One Plus, 
One Compa) 

 

Input pulse value first 
external meter 
(0,25 to 10.000 L/pulse) * 

 

Input pulse value second 
external meter 
(0,25 to 10.000 L/pulse.) * 

 

Set date 

 

Set time * 

 

Set target day 

Содержание SENSUS PolluTherm Integrator

Страница 1: ...t into the heat meter 11 11 8 Combined heating cooling meter ordering option 11 11 9 Optional integrated data logger ordering option 12 11 10 Retrofitting from battery unit to power supply unit 12 12...

Страница 2: ...tection Only specially trained and authorized personnel are permitted to carry out the connection Moreover attention is to be paid to the national technical rules Voltage 220 240 V AC or 24 V AC Frequ...

Страница 3: ...g systems It is recommended to install the flow sensor in the warmer line return pipe of the cooling device PolluTherm X installation in warmer line has to be used Please note the approved minimum tem...

Страница 4: ...of the pipe diameter Refer to the following guide for installing such temperature sensors Nominal sizes DN 50 Install the temperature sensors in an angle of 45 towards the flow direction see figure 4...

Страница 5: ...8 Four wire connection 7 8 und 3 4 Screening if any Start by removing the appropriate preshaped rubber part from the integrator housing see figure 7 Then pull the cable through the hole in the presha...

Страница 6: ...ntervals of 4 seconds and shows the accumulated heat energy By a push on the red key the first display item in the user menu accumulated heat energy is activated The other five menus can be obtained b...

Страница 7: ...es on an adjustable annual target Target day value for heat and cooling energy resp Target day value for volume Target day value for tariff 1 if activated Target day value for tariff cold if activated...

Страница 8: ...play shows a month selectionor wait for five minutes 8 4 Service menu example Each display item is marked with a man symbol The service menu shows maximum values and meter settings Absolute maximum fl...

Страница 9: ...t three digits of the eight digit serial number on the meter housing At the beginning 000 appears Push the key for approx 2 seconds the zero on the left side starts flashing By continuously pushing th...

Страница 10: ...ow temperature sensors In most cases the error situation Err 1010 is caused by temporary system conditions where the temperature in the warmer line drops by at least 3K below the temperature in the co...

Страница 11: ...r reading 0 00 m The activation of the inputs has to be done via the service software MiniCom menu item set pulse input parameters The meter IDs of the pulse meters have to be set there as well as the...

Страница 12: ...only the screw on the right side under the KK1 seal user seal of the plastic cover Pull the integrated module forward from the connection The seals in the middle and on the left side may not be remove...

Страница 13: ...the lower 3 and 4 the electric resistance of the extension cable or cables does do not influence the measurement and the reading of the temperatures Material number 28505033 Edition 007 August 2019 Su...

Страница 14: ...Heat Cooling meter integrator PolluTherm Installation and operational instructions M H 6111 INT PolluTherm page 14 Annex 1 Declaration of conformity acc directive 2004 22EC MID...

Отзывы: