Xylem Lowara LS Series Скачать руководство пользователя страница 20

Installation, Operating and Maintenance Instruction

                            Model LS, LC, LCP

 

 
 

 

LS 100-english

 

page 18

 

 

Artikel No. 771073402 

 

 

8.4 Removal of Impeller 

 

 

Note attached "Mounting Instruction for Shaft 
Sealing".

 

 

 

Loosen impeller nut (28) (right threaded) by fixing 
the rotor at the coupling end. 

 

Draw off the impeller (1) with two screw drivers or 
pry bars (picture 10). Remove key (PF1). 

 

 

 

 

           pic 10 

 

 

Be sure to locate pry bars under impeller vanes 
to prevent damage to the impeller.

 

 

 

For further dismounting the Back Pull Out 
Assembly should be placed in the vertical position 
(with vertical shaft, see picture 11). Attention: 
Precautions should be taken to prevent the Back 
Pull Out Assembly from tipping! 

 
 
 
 
 
 
 
 
pic 11 
 
 
 
 
 
 

 

8.5 Removal of Shaft Sealing 

 

Before you remove the casing cover (18..) notice 
"Mounting Instructions for Shaft Sealing". 

 

8.6 Removal of Bearing 

 

Remove coupling with a coupling puller (picture 
12), remove coupling key (PF2). 

 

  

pic 12 

 

 

Remove the flinger (73). 

 

Loosen and remove hexagon screws (S5) resp. 
hexagon nuts (M5), remove the lantern (11). 

 

Only for bearing bracket 100S: Unscrew the 
hexagon nuts (M8) and demount the bearing 
cover (12/P). 

 

Loosen and remove the hexagon screws (S6), 
remove the bearing cover (12). 

 

Move the shaft (24) with the pair of angular 
contact bearings (K2) and the inner ring of the 
roller bearing (K1) with haps by a wood or plastic 
hammer with caution to the drive end (picture 13). 

 

picture 13 

 

 

Demount the roller bearing (K1) (cage) off the 
bearing bracket (10). 

 

Bend up the lock washer (SB), unscrew the 
bearing nut (50) (right threaded), remove the lock 
washer (SB). 

 

Heat up the angular contact bearings (K2) and the 
inner ring of the roller bearing (K1) and remove it 
with qualified tools (e.g. with hook proof-puller) 
from the shaft (24). 

 

8.7 Reconditioning 

After disassembly all parts must be cleaned and 
checked for wear carefully. Worn or damaged parts 
must be replaced by new parts (spare parts). 
When reassembling the pump it is recommended to 
replace all seals (flat gaskets, o-rings and radial shaft 
seal rings). 

 

 

All sealing materials of PTFE resp. Graphite are 
intended for being used only once.

 

 

In most cases it make sense, if damaged absolutely 
necessary, to renew the mechanical seal and the 
bearings. 
Deposits on the impeller (1), on the volute casing (4) 
or on the casing cover (18) must be removed. 
 
 
 
 
 
 

Содержание Lowara LS Series

Страница 1: ...920 en Volute Casing Pumps Model LS LC LCP Installation Operation and Maintenance Instruction Translation of the Original Operation Manual en Keep for further use Pay attention to this operating instr...

Страница 2: ...Xylem Service Austria GmbH Ernst Vogel Stra e 2 A 2000 Stockerau Telefon 43 0 2266 604 Fax 43 0 2266 65311 E Mail info austria xyleminc com Internet www xylemaustria com...

Страница 3: ...Handling Storage 9 4 1 Transport Handling 9 4 2 Storage Conservation 10 5 Mounting Installation 10 5 1 Mounting of Pump Unit 10 5 2 Connection of Pipings to the Pump 10 5 3 Coupling 11 5 4 Drive 12 5...

Страница 4: ...ies to the manufacturer resp orders of spare ATEX Label only for pumps in compliance with EC directive 94 9 EG CE Marking of compliance with the EC directive 94 9 EG Ex specific marking for explosion...

Страница 5: ...ir work during the guarantee period may only be carried out by us or subject to our written approval Otherwise the guarantee ceases to apply Longer term guarantees basically only cover correct handlin...

Страница 6: ...danger to people or the environment The provisions of the law must be observed Measures should be taken to exclude any danger from electricity e g by complying with the local regulations on electrica...

Страница 7: ...n t cause additional increase of surface temperature at the pump Furthermore the references in chapter 6 of these operating Instructions must be taken into consideration On pumps with mech seals the p...

Страница 8: ...is is valid for the operation as well as for the standstill of the pump and therefore for all possible pressures and temperatures of the unit 2 8 3 NPSH The pumped liquid must have a min pressure NPSH...

Страница 9: ...ng with barrier by pumped fluid P3 Packing with lantern ring with barrier by external fluid P4 Packing with lantern ring with flush P5 Packing without lantern ring with external cooling Position 4 Mat...

Страница 10: ...76 0 75 5 76 5 76 5 90 0 77 0 76 5 77 5 77 5 110 0 78 0 77 5 77 0 79 0 78 5 80 0 132 0 79 0 78 5 78 0 79 5 79 5 80 0 160 0 80 0 79 5 79 0 80 5 81 0 80 5 200 0 81 5 81 0 80 5 81 5 82 0 83 0 250 0 82 5...

Страница 11: ...200 6000 5400 6700 10450 3250 2300 2650 4800 200 400 250 8350 7450 6750 13050 4450 3150 3650 6550 200 6000 5400 6700 10450 3250 2300 2650 4800 200 500 250 8350 7450 6750 13050 4450 3150 3650 6550 200...

Страница 12: ...ufficient firmness acc to DIN 1045 or equal standard min BN 15 to ensure a secure functional mounting The concrete foundation must have set before the unit is erected Its surface must be horizontal an...

Страница 13: ...ed in the suction intake pipe when the motor is being started up If the pipe system is tested with the pump installed do not exceed the maximum permitted casing pressure of the pump and or shaft seali...

Страница 14: ...available and correct if necessary Pay attention to chapter 6 beforehand It must be possible to turn the unit easily and harmoniously by hand Improper alignment of the unit can lead to damages at coup...

Страница 15: ...ty devices are operational Switch on any sealing flushing or cooling devices that are provided See data sheet for quantity and pressure Open valve in suction intake pipe Set discharge side valve to ap...

Страница 16: ...valid 6 5 Lubrication of Bearings 6 5 1 Oil lubrication The bearing bracket must be filled up with oil For quality of oil refer to chapter 7 4 1 For quantity of oil refer to chapter 7 4 1 The pumps a...

Страница 17: ...ooled down If there is any risk of freezing empty pump cooling areas and pipes completely If the pump also remains under operating conditions pressure and temperature when stationary leave all sealing...

Страница 18: ...ure 46 4 mm 2 s 175 C 15 C higher than permitted bearing temperature For ambient temperatures under 10 C another suitable type of lubrication oil must be used Request required Oil quantity Bearing bra...

Страница 19: ...isassembled pumps units or single parts against tipping over or rolling off While disassembling the pump use of an open flame blowlamp etc only when there is no danger of setting fire cause an explosi...

Страница 20: ...100S Unscrew the hexagon nuts M8 and demount the bearing cover 12 P Loosen and remove the hexagon screws S6 remove the bearing cover 12 Move the shaft 24 with the pair of angular contact bearings K2...

Страница 21: ...ng the reverse order of steps as completed for pump disassembly However the following observations should be considered Pay attention to the utmost cleanliness when reassembling the pump For tight tol...

Страница 22: ...arings aso 2 To ensure optimum availability we recommend that suitable quantities of spare parts are held in stock especially if these are made from special materials and in the case of mechanical sea...

Страница 23: ...liquid level check if suction pipe is vacuum tight Air being sucked in through shaft sealing clean sealing pipe increase sealing pressure replace shaft sealing Direction of rotation is wrong swap ove...

Отзывы: