Xylem Lowara LS Series Скачать руководство пользователя страница 11

Installation, Operating and Maintenance Instruction

                            Model LS, LC, LCP

 

 
 

 

LS 100-english

 

page 9

 

 

Artikel No. 771073402 

 

 

Sizes 

Suction nozzle 

Discharge nozzle 

DN 

Forces in N 

Torques in Nm 

DN 

Forces in N 

Torques in Nm 

Fx 

Fy 

Fz 

Mx 

My 

Mz 

Fx 

Fy 

Fz 

Mx 

My 

Mz 

LS, LC 

125-330 

150 

4000  3600  3240  6280  2000  1400  1640  2920 

125 

2840  2560  3160  4960  1680  1200  1520  2440 

125-500 

150 

4000  3600  3240  6280  2000  1400  1640  2920 

125 

2840  2560  3160  4960  1680  1200  1520  2440 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150-500 

200 

5360  4800  4320  8360  2600  1840  2120  3840 

150 

3600  3240  4000  6280  2000  1400  1640  2920 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200-260 

250 

6680  5960  5400  10440  3560  2520  2920  5240 

200 

4800  4320  5360  8360  2600  1840  2120  3840 

200-350 

250 

6680  5960  5400  10440  3560  2520  2920  5240 

200 

4800  4320  5360  8360  2600  1840  2120  3840 

200-400 

250 

6680  5960  5400  10440  3560  2520  2920  5240 

200 

4800  4320  5360  8360  2600  1840  2120  3840 

200-500 

250 

6680  5960  5400  10440  3560  2520  2920  5240 

200 

4800  4320  5360  8360  2600  1840  2120  3840 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250-315 

300 

8000  7160  6440  12520  4840  3440  3960  7120 

250 

5960  5400  6680  10440  3560  2520  2920  5240 

250-350 

300 

8000  7160  6440  12520  4840  3440  3960  7120 

250 

5960  5400  6680  10440  3560  2520  2920  5240 

250-400 

300 

8000  7160  6440  12520  4840  3440  3960  7120 

250 

5960  5400  6680  10440  3560  2520  2920  5240 

250-500 

300 

8000  7160  6440  12520  4840  3440  3960  7120 

250 

5960  5400  6680  10440  3560  2520  2920  5240 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300-400 

350 

9320  8360  7520  14600  6200  4400  5080  9120 

300 

7160  6440  8000  12520  4840  3440  3960  7120 

300-450 

350 

9320  8360  7520  14600  6200  4400  5080  9120 

300 

7160  6440  8000  12520  4840  3440  3960  7120 

300-500 

350 

9320  8360  7520  14600  6200  4400  5080  9120 

300 

7160  6440  8000  12520  4840  3440  3960  7120 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

350-450 

400  10640  9560  8600  16680  7760  5520  6360  11440  350 

8360  7520  9320  14600  6200  4400  5080  9120 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400-400 

400  10640  9560  8600  16680  7760  5520  6360  11440  400 

9560  8600  10640  16680  7760  5520  6360  11440 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600-600 

600  15920  14360  12920  25000  16160  11520  13280  23920  600  14360  12920  15920  25000  16160  11520  13280  23920 

 

LCP 

125-500 

150 

5000  4500  4050  7850  2500  1750  2050  3650 

125 

3550  3200  3950  6200  2100  1500  1900  3050 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150-500 

200 

6700  6000  5400  10450  3250  2300  2650  4800 

150 

4500  4050  5000  7850  2500  1750  2050  3650 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200-260 

250 

8350  7450  6750  13050  4450  3150  3650  6550 

200 

6000  5400  6700  10450  3250  2300  2650  4800 

200-350 

250 

8350  7450  6750  13050  4450  3150  3650  6550 

200 

6000  5400  6700  10450  3250  2300  2650  4800 

200-400 

250 

8350  7450  6750  13050  4450  3150  3650  6550 

200 

6000  5400  6700  10450  3250  2300  2650  4800 

200-500 

250 

8350  7450  6750  13050  4450  3150  3650  6550 

200 

6000  5400  6700  10450  3250  2300  2650  4800 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250-315 

300  10000  8950  8050  15650  6050  4300  4950  8900 

250 

7450  6750  8350  13050  4450  3150  3650  6550 

250-350 

300  10000  8950  8050  15650  6050  4300  4950  8900 

250 

7450  6750  8350  13050  4450  3150  3650  6550 

250-400 

300  10000  8950  8050  15650  6050  4300  4950  8900 

250 

7450  6750  8350  13050  4450  3150  3650  6550 

250-500 

300  10000  8950  8050  15650  6050  4300  4950  8900 

250 

7450  6750  8350  13050  4450  3150  3650  6550 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300-400 

350  11650  10450  9400  18250  7750  5500  6350  11400  300 

8950  8050  10000  15650  6050  4300  4950  8900 

300-450 

350  11650  10450  9400  18250  7750  5500  6350  11400  300 

8950  8050  10000  15650  6050  4300  4950  8900 

300-500 

350  11650  10450  9400  18250  7750  5500  6350  11400  300 

8950  8050  10000  15650  6050  4300  4950  8900 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

350-450 

400  13300  11950  10750  20850  9700  6900  7950  14300  350  10450  9400  11650  18250  7750  5500  6350  11400 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400-400 

400  13300  11950  10750  20850  9700  6900  7950  14300  400  11950  10750  13300  20850  9700  6900  7950  14300 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600-600 

600  19900  17950  16150  31250  20200  14400  16600  29900  600  17950  16150  19900  31250  20200  14400  16600  29900 

 

4. Transport, Handling, Storage 

4.1 Transport, Handling 

 

Check the pump / pump unit immediately upon 
delivery / receipt of despatch for damage or 
missing parts. 

 

The pump / pump unit must be transported 
carefully and by competent personnel. Avoid 
serious impacts. 

 

Keep the pump/pump unit in the same position in 
which it was supplied from the factory. Take note 
of the instructions on the packaging. 

 

The suction and discharge side of the pump must 
be closed with plugs during transport and storage. 

 

 

Dispose of all packing materials in accordance 
with local regulations.

 

 

 

Lifting devices (e.g. fork-lift truck, crane, crane 
device, pulleys, sling ropes, etc.) must be 
sufficiently strong and must only be used by 
authorized persons. The weight of the pump / 
pump unit is given in the data sheet. 

 

The pump / pump unit may only be lifted by solid 
points such as the  casing, flanges or frame. 

Picture 2 shows the correct method of carrying by 
crane. 

 

 

           pic 2 

 

 

Do not stand underneath suspended loads.  
Take note of the general regulations on 
prevention of accidents. 
The pump / pump unit must be secured against 
tipping over and slipping until it has been fixed 
in its final location.

 

 

 

Sling ropes must not be fixed to ends of shafts 
or the ring loops of the motor.

 

 

Содержание Lowara LS Series

Страница 1: ...920 en Volute Casing Pumps Model LS LC LCP Installation Operation and Maintenance Instruction Translation of the Original Operation Manual en Keep for further use Pay attention to this operating instr...

Страница 2: ...Xylem Service Austria GmbH Ernst Vogel Stra e 2 A 2000 Stockerau Telefon 43 0 2266 604 Fax 43 0 2266 65311 E Mail info austria xyleminc com Internet www xylemaustria com...

Страница 3: ...Handling Storage 9 4 1 Transport Handling 9 4 2 Storage Conservation 10 5 Mounting Installation 10 5 1 Mounting of Pump Unit 10 5 2 Connection of Pipings to the Pump 10 5 3 Coupling 11 5 4 Drive 12 5...

Страница 4: ...ies to the manufacturer resp orders of spare ATEX Label only for pumps in compliance with EC directive 94 9 EG CE Marking of compliance with the EC directive 94 9 EG Ex specific marking for explosion...

Страница 5: ...ir work during the guarantee period may only be carried out by us or subject to our written approval Otherwise the guarantee ceases to apply Longer term guarantees basically only cover correct handlin...

Страница 6: ...danger to people or the environment The provisions of the law must be observed Measures should be taken to exclude any danger from electricity e g by complying with the local regulations on electrica...

Страница 7: ...n t cause additional increase of surface temperature at the pump Furthermore the references in chapter 6 of these operating Instructions must be taken into consideration On pumps with mech seals the p...

Страница 8: ...is is valid for the operation as well as for the standstill of the pump and therefore for all possible pressures and temperatures of the unit 2 8 3 NPSH The pumped liquid must have a min pressure NPSH...

Страница 9: ...ng with barrier by pumped fluid P3 Packing with lantern ring with barrier by external fluid P4 Packing with lantern ring with flush P5 Packing without lantern ring with external cooling Position 4 Mat...

Страница 10: ...76 0 75 5 76 5 76 5 90 0 77 0 76 5 77 5 77 5 110 0 78 0 77 5 77 0 79 0 78 5 80 0 132 0 79 0 78 5 78 0 79 5 79 5 80 0 160 0 80 0 79 5 79 0 80 5 81 0 80 5 200 0 81 5 81 0 80 5 81 5 82 0 83 0 250 0 82 5...

Страница 11: ...200 6000 5400 6700 10450 3250 2300 2650 4800 200 400 250 8350 7450 6750 13050 4450 3150 3650 6550 200 6000 5400 6700 10450 3250 2300 2650 4800 200 500 250 8350 7450 6750 13050 4450 3150 3650 6550 200...

Страница 12: ...ufficient firmness acc to DIN 1045 or equal standard min BN 15 to ensure a secure functional mounting The concrete foundation must have set before the unit is erected Its surface must be horizontal an...

Страница 13: ...ed in the suction intake pipe when the motor is being started up If the pipe system is tested with the pump installed do not exceed the maximum permitted casing pressure of the pump and or shaft seali...

Страница 14: ...available and correct if necessary Pay attention to chapter 6 beforehand It must be possible to turn the unit easily and harmoniously by hand Improper alignment of the unit can lead to damages at coup...

Страница 15: ...ty devices are operational Switch on any sealing flushing or cooling devices that are provided See data sheet for quantity and pressure Open valve in suction intake pipe Set discharge side valve to ap...

Страница 16: ...valid 6 5 Lubrication of Bearings 6 5 1 Oil lubrication The bearing bracket must be filled up with oil For quality of oil refer to chapter 7 4 1 For quantity of oil refer to chapter 7 4 1 The pumps a...

Страница 17: ...ooled down If there is any risk of freezing empty pump cooling areas and pipes completely If the pump also remains under operating conditions pressure and temperature when stationary leave all sealing...

Страница 18: ...ure 46 4 mm 2 s 175 C 15 C higher than permitted bearing temperature For ambient temperatures under 10 C another suitable type of lubrication oil must be used Request required Oil quantity Bearing bra...

Страница 19: ...isassembled pumps units or single parts against tipping over or rolling off While disassembling the pump use of an open flame blowlamp etc only when there is no danger of setting fire cause an explosi...

Страница 20: ...100S Unscrew the hexagon nuts M8 and demount the bearing cover 12 P Loosen and remove the hexagon screws S6 remove the bearing cover 12 Move the shaft 24 with the pair of angular contact bearings K2...

Страница 21: ...ng the reverse order of steps as completed for pump disassembly However the following observations should be considered Pay attention to the utmost cleanliness when reassembling the pump For tight tol...

Страница 22: ...arings aso 2 To ensure optimum availability we recommend that suitable quantities of spare parts are held in stock especially if these are made from special materials and in the case of mechanical sea...

Страница 23: ...liquid level check if suction pipe is vacuum tight Air being sucked in through shaft sealing clean sealing pipe increase sealing pressure replace shaft sealing Direction of rotation is wrong swap ove...