WS001348A
c) Pull off the impeller.
6. Remove the lower diffuser.
4x
7. Remove the inner diffuser.
8. Remove the upper diffuser.
9. Remove the impeller:
a) Lock the impeller to prevent rotation.
Use pliers, a screwdriver, or similar.
b) Turn the adjustment screw counterclockwise until the impeller breaks free from
the shaft.
Use a 10 mm hexagon bit adapter (Allen socket) with a 100 mm (4 in.) extension.
Maintenance
30
Flygt 2860.180 Installation, Operation, and Maintenance Manual
Содержание Flygt 2860.180
Страница 1: ...Installation Operation and Maintenance Manual Flygt 2860 180...
Страница 2: ......
Страница 41: ...4x WS001341A Maintenance Flygt 2860 180 Installation Operation and Maintenance Manual 39...