WS006960A
Fill with oil
1. Replace the oil screw O-ring.
2. Put one of the oil screws back and tighten it.
3. Turn the pump so that the oil hole faces upwards and fill with new oil.
Fill until the oil level reaches the inlet hole.
Quantity: 1.45 L (1.53 qt)
4. Put the oil screw back and tighten it.
Replace the impeller
Remove the impeller MT, HT
WARNING:
A worn impeller and/or pump housing can have very sharp edges. Wear protective
gloves.
1. Remove the strainer.
Maintenance
26
Flygt 2860.180 Installation, Operation, and Maintenance Manual
Содержание Flygt 2860.180