WARNING:
• Make sure that the unit cannot roll or fall over and injure people or damage property.
• In some installations, the pump and the surrounding liquid may be hot. Bear in mind
the risk of burn injuries.
• Make sure nobody is close to the unit when it is started. The unit will jerk in the
opposite direction of the impeller rotation.
NOTICE:
Make sure that the rotation of the impeller is correct. For more information, see Check the
impeller rotation.
1. Inspect the pump. Check that there is no physical damage to the pump or cables.
2. Check the oil level in the oil housing.
3. Remove the fuses or open the circuit breaker, and check that the impeller can be
rotated freely.
4. Check that the monitoring equipment (if any) works.
5. Check that the impeller rotation is correct.
6. Start the pump.
Clean the pump
The pump must be cleaned if it has been running in very dirty water. If clay, cement or
other similar dirt is left in the pump it may clog the impeller and seal, preventing the
pump from working.
Let the pump run for a while in clean water, or flush it through the discharge connection.