4115T Light Duty Industrial PC Appendix B – Watchdog
Timer
57 143926(A)
Example assembly program:
; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:
MOV AX, 6F02H
;setting the time-out value
MOV BL, 30
;time-out value is 48 seconds
INT
;15H
;
; ADD YOUR APPLICATION PROGRAM HERE
;
CMP EXIT_AP, 1 ;is your application over?
JNE W_LOOP ;No, restart your application
MOV AX, 6F02H ;disable Watchdog Timer
MOV BL, 0 ;
INT 15H
;
; EXIT
;
Содержание 4115T
Страница 1: ...2005 XYCOM AUTOMATION INC Printed in the United States of America 4115T 15 Light Duty Industrial PC...
Страница 14: ...4115T Thin Line Industrial Flat Panel PC Chapter 2 Installation 10 143926 A Figure 2 3 Panel Mounting Diagram...
Страница 16: ...4115T Thin Line Industrial Flat Panel PC Chapter 2 Installation 12 143926 A Figure 2 5 Wall Mounting Diagram...
Страница 53: ...4115T Light Duty Industrial PC Chapter 5 Troubleshooting 49 143926 A Figure 5 1 Serial Loopback Connections...