46 143926(A)
Chapter 4 – Maintenance
The 4115T is designed to withstand the harsh environment of the factory floor.
Routine maintenance can help keep your system in good operating condition.
Preventive maintenance consists of several basic procedures that will greatly reduce
the chance of system malfunction. Schedule preventive maintenance along with the
regular equipment maintenance to minimize down time.
General Preventive Maintenance
Here are some preventive measures you can take:
•
Clean the monitor screen using a non-residue cleaner such as a mild window
cleaning solution or CRT screen cleaner. Take care not to scratch the screen face.
•
Remove dust and dirt from PC components
. If dust builds up on heat sinks and
circuitry, an obstruction of heat dissipation could cause the unit to malfunction. If
dust reaches the electronic boards, a short circuit could occur.
•
Check the connections to I/O modules,
especially in environments where
vibration could loosen the connections. Check to see that all plugs, sockets,
terminal strips, and module connections are solid.
•
Remove unnecessary articles, such as drawings or manuals, from the unit.
They
can obstruct airflow and create hot spots, which cause the system to malfunction.
•
Do not place noise-generating equipment near the 4115T unit.
Fuse Replacement
The 4115T unit has no accessible fuse. Return the unit to the factory for fuse
replacement.
Recommended Hard Drive Preventive Maintenance
Xycom Automation has recognized that hard drive failures may begin to increase an
average of four to five years into the life of most computers used in industrial
applications. Therefore, it is our recommendation as a preventive maintenance
measure that all hard drives used in these types of applications be replaced before the
four to five year time period to avoid any down time related to hard drive failure.
The purpose of this message is to merely bring this to our customer’s attention, to
offer alternative solutions, and to provide all of our customers with the excellent
service they deserve.
Содержание 4115T
Страница 1: ...2005 XYCOM AUTOMATION INC Printed in the United States of America 4115T 15 Light Duty Industrial PC...
Страница 14: ...4115T Thin Line Industrial Flat Panel PC Chapter 2 Installation 10 143926 A Figure 2 3 Panel Mounting Diagram...
Страница 16: ...4115T Thin Line Industrial Flat Panel PC Chapter 2 Installation 12 143926 A Figure 2 5 Wall Mounting Diagram...
Страница 53: ...4115T Light Duty Industrial PC Chapter 5 Troubleshooting 49 143926 A Figure 5 1 Serial Loopback Connections...