5.3.1
Restore system defaults procedure
1.
Disconnect the input power connecter to power down the unit.
2.
While pressing and holding down the
SW
button (long press), reconnect the input power.
Continue pressing and pay attention to the behavior of the
STAT
LED:
3.
After approximately 10 seconds, All LEDs blink in orange, as shown in Figure 33 below. At
this point, release the
SW
button. System defaults will be restored.
Figure 33: Release SW Button to Begin Restoring Defaults
4.
At the end of the process, the
STAT and the PWR
LED should appear in solid green, as
shown in Figure 34 below.
Figure 34: System Defaults Successfully Restored
5.3.2
System Recovery
In the event of firmware malfunction (Unit is not responding or no access to the unit), perform a
system recovery
to restore normal operation.