XVC-ULTRA Encoder
User’s Guide
Page 43 of 50
Overheating
The
STAT
LED serves as an indicator of system overheating. The following table provides guidelines
for handling the system in an overheating scenario.
NOTE
The STAT LED is used for multiple types of indications in a variety of processes. Note that
overheating and fan
malfunction alarms have the highest priority, and always override all other indications
.
Table 23: Overheating Conditions
Status
STAT LED Behavior Encoder Behavior
Normal temperature
Green
Normal
Fan failure
Red
Fan failures:
•
Fan not detected by the software
•
Fan operate under the minimum required
speed: 500 RPM.
Critical temperature
Red, slow blink
The unit resets after 60 seconds. Upon reset,
only basic infrastructure and functionality are
enabled – CPU, memories, peripherals, and
communications. Full operation resumes upon
return to Normal status.
Emergency
Red, fast blink
System is powered off after 30 seconds. Re-
powering is required.
Restoring System Defaults
Perform the following operations if you need to restore the factory system defaults.
NOTE
During factory defaults the IP address of the encoder will be set to 169.x.x.x. The x.x.x is derived from the MAC
address. Encoder parameters are set default, streaming mode is set to TS-UDP. The actual IP address can be
discovered using the
XVC
management tool.