Installation Guide
P. 11
Options Programming
MODE 1
*indicates default setting
FUNCTION 1 – Ignition-controlled Door Locks
OPTION 1*
Ignition Locks DISABLED
OPTION 2
Ignition Locks ENABLED
OPTION 3
Ignition UNLOCK only
OPTION 4
Ignition LOCK only
FUNCTION 2 – Secure Lock
OPTION 1*
Secure Lock DISABLED (1-second Disarm pulse)
OPTION 2
Smart Secure Lock ENABLED
OPTION 3
Secure Lock DISABLED (1/2-second Disarm pulses)
OPTION 4
Standard Secure Lock
FUNCTION 3 – Passive / Active Starter Kill
OPTION 1*
Starter Kill PASSIVE (1-minute timeout)
OPTION 2
Starter Kill ACTIVE
OPTION 3
Starter Kill PASSIVE (3-minute timeout)
FUNCTION 4 – Door Locks Timing
OPTION 1*
7/10-sec. LOCK / UNLOCK pulses
OPTION 2
4-sec. LOCK / UNLOCK pulses
OPTION 3
a single 7/10-sec. LOCK pulse and two 1/4-sec. UNLOCK pulses
OPTION 4
1/10-sec. LOCK and 1/10-sec. UNLOCK pulses
FUNCTION 5 – LED flashing
OPTION 1*
ENABLED (without starter kill
Æ
will flash only when ignition is OFF)
OPTION 2
DISABLED
OPTION 3
ENABLED
(with starter kill
Æ
will flash when the starter kill engages.
This option should be selected
ONLY
if the starter kill is installed.)
MODE 2
*indicates default setting
FUNCTION 1 – Safe Start Mode
OPTION 1 Safe Start
ENABLED
OPTION 2*
Safe Start DISABLED
OPTION 3 Swap Start:
●
START
signal =
LOCK
+
UNLOCK
buttons
●
AUX 2
signal =
START/STOP
button
FUNCTION 2 – Engine Run Time
OPTION 1 Run time = 4 minutes in Gas Mode / 9 minutes in Diesel Mode
OPTION 2*
Run time = 15 minutes in Gas Mode / 20 minutes in Diesel Mode
OPTION 3 Run time = 25 minutes in Gas Mode / 30 minutes in Diesel Mode
FUNCTION 3 – Idle/Turbo Mode
OPTION 1 Idle/Turbo Mode
DISABLED
OPTION 2*
Idle/Turbo Mode
ENABLED
OPTION 3 Idle/Turbo Mode
DISABLED
FUNCTION 4 – Gas or Diesel Mode
OPTION 1 Diesel Engine (Cold Weather Mode run time = 20 min.)
OPTION 2*
Gasoline Engine
OPTION 3 Diesel Engine (Cold Weather Mode run time = 9 min.)
FUNCTION 5 – Ignition Valet
OPTION 1 Disabled