Installation and User Manual
ADPRO FastTx by Xtralis
104
Doc 11949_06
Exit Path and Delay
Figure 105: Exit Path and Delay Settings
When arming a site (i.e. set into the Secure Mode), alarms, and their associated images
originating from the Exit Path Zones are ignored until the end of the Exit Path Delay period,
allowing the user to exit the site.
Once the Exit Path Delay period expires, any Alarm Input will be processed immediately. In this
scenario, all pending alarms will also be processed immediately and the Exit Path Delay timer
cancelled.
Note that any other alarm originating from a zone that is not in the Exit Path Zones list, will be
processed immediately.
Exit Path Zone(s) create a controlled route between the location where the Fast Trace can be
Armed and an Exit Point. To create an Exit Path, a list of Exit Path Zones must be specified.
Up to ten zones can be designated on the Exit Path.
Highlight the Alarm Input number or camera to be assigned to the Exit Path Zone in the left pane,
and then use the arrows to add or remove the zones in the Path pane on the right.
The Exit Delay is the maximum time allowed (in seconds) between arming the system and the
reporting of alarms.
Options:
0 - 300 seconds, where 0 disables the Exit Delay
Factory Default:
30
seconds