Doc. 20780_03
19
ADPRO Passive-Infrared (PIR) PRO Series by Xtralis
Planning and Commissioning Manual
The monitoring of the area needs not be complete, but should be as full as possible. This
corresponds to a continuous coverage strategy. A criminal must get to the middle of the
area, regardless of which side he uses for his attempt to enter.
5.4.3.2 Planning
Because of these circumstances, ideally only volumetric detectors should be used.
Depending on the size of the area the following detectors might be considered:
PRO-18,
PRO-18H
PRO-30
PRO-40
PRO-51
PRO-85,
PRO-85H
In this case a standard volumetric PRO-30 was chosen.
NOTE!
This is a very suitable arrangement for programming an A/B alarm or
cross zoning of two detectors. It may be possible to dispense with a
range termination, because an alarm will be triggered only, if the two
detectors within the perimeter boundary are activated.
5.4.4
Extensive Monitoring, or Monitoring of Borders, such as of a
Country
5.4.4.1 Requirements
An absolutely seamless and very secure monitoring of an elongated, large area, or of a
country’s borders, for the use of the security services.
The highest possible detection rate will be assumed. The false alarm rate should be in a
framework that can be mapped by an organisation (border monitoring: c. 10-12%).
5.4.4.2 Planning
Because of these circumstances, normally a curtain detector with a very large nominal range
should be used.
Depending on the application the following detectors might be considered:
PRO-45,
PRO-45H,
PRO-45D, PRO-45DH
PRO-100,
PRO-100H
PRO-250H