39 / 99
www.xovis.com
The time span between the minimum and maximum dwell time is divided into 10 bins of
equal size for dwell time distribution. See also chapter 3.2.9.1.1
“
Count zone charts
” for
more details on this.
For meaningful dwell time statistics, it is important to place the zone correctly inside the
sensor actual tracking area. Only tracks started and ended outside the zone are
considered for dwell time calculation. Please refer to chapter 4.3
“
Placement of dwell
zones
”
for more information on this.
3.2.7.10
Privacy mode
After setting up the counting items, the next screen allows to define the privacy mode. The
sensor offers 4 level of privacy:
Level
0
No restrictions. Live video of the scene as well as tracking is shown without any
restrictions.
1
Only a still image of the scene is shown, no video stream. This still image can
be refreshed on request. Tracking is shown without restrictions.