APPENDIX B: BOOT STATUS CODES (RUN_STATUS)
The following table describes the Boot status codes returned by the startup processes accessible
though the GET_RUN_STATUS control utility command.
CODE
LABEL
NOTE
0
INIT
Reserved initial value. Decline attempts to initiate DFU.
1
DATA_PARTITION_NOT_FOUND
Not used.
2
FACTORY_DATA_SUCCESS
Normal operation.
3
UPGRADE_DATA_SUCCESS
Normal operation.
4
FACTORY_DATA_IN_PROGRESS
Image scanning in progress. Decline attempts to initiate DFU.
5
UPGRADE_DATA_IN_PROGRESS
Image scanning in progress. Decline attempts to initiate DFU.
6
DFU_IN_PROGRESS
Enough DFU commands received to establish a connection to on-board flash
memory. Not cleared until reboot.
7
HW_BUILD_READ_SUCCESS
Reserved intermediate value. Normally never returned.
8
HW_BUILD_PARTITION_SIZE_ERROR
Problem reading data partition header. Check factory programming.
9
HW_BUILD_PARTITION_BASE_ERROR
Problem reading data partition header. Check factory programming.
10
HW_BUILD_READ_ERROR
Problem reading data partition header. Check factory programming.
11
HW_BUILD_CRC_ERROR
Problem reading data partition header. Check factory programming. May indicate
that no data partition is present or a flash wear issue.
12
HW_BUILD_TAG_ERROR
Problem reading data partition header. Check factory programming.
13
FACTORY_VERSION_ERROR
No valid upgrade image found. A factory image did not match running version. This
can indicate fail-safe mode.
14
UPGRADE_VERSION_ERROR
Valid upgrade boot and data images found but data image version does not match
running version. Check correct version of deployed field upgrade.
15
FACTORY_ITEM_READ_ERROR
Problem reading configuration items from data image. Unexpected error.
16
UPGRADE_ITEM_READ_ERROR
Problem reading configuration items from data image. Unexpected error.
17
FACTORY_ITEM_INVALID_TYPE
Last item encountered is not of terminator type. Should never happen with script
generated data images. Check generation procedure.
18
UPGRADE_ITEM_INVALID_TYPE
Last item encountered is not of terminator type. Should never happen with script
generated data images. Check generation procedure.
19
DFU_FLASH_CONNECT_FAILED
Failed to establish on-board flash connection. Check factory programming. Check
flash specification (see section below).
20
DFU_FLASH_SPEC_UNSUITABLE
Flash specification unsuitable for DFU. Check flash specification (see section
below).