xiB & xiB-64 - Technical Manual Version 1.06
70
4.3.2.2.
Triggered acquisition - burst of frames
Frame Burst Start
In this mode each trigger pulse triggers defined number of exposed frames.
figure 4-3, triggered burst of frames – frame burst start, number of frames in burst set to 3
Frame Burst Active
If trigger is level sensitive it can be used to control image acquisition.
figure 4-4, triggered burst of frames – frame burst active
Please see:
Frame Burst Modes: https://www.ximea.com/support/wiki/allprod/Frame_Burst_Modes
4.3.2.3.
Exposure defined by trigger pulse length
In this mode the exposure is defined by trigger pulse length. This can be used to achieve longer exposure than allowed by API.
Also it can be used to trigger several images in sequence with different exposure time. Exposure time is measured and reported
in image metadata.
figure 4-5, Exposure defined by trigger pulse length
Please see:
Exposure Defined by Trigger Pulse Length:
https://www.ximea.com/support/wiki/allprod/Exposure_Defined_by_Trigger_Pulse_Length