xiB & xiB-64 - Technical Manual Version 1.06
14
3.
Hardware Specification
3.1.
Power Supply
The xiB and xiB-64 cameras are powered via their respective sync cables (CBL-CB-PWR-SYNC-3M0 (xiB) and CBL-MT-PWR-
SYNC-3M0 (xiB-64)). See section
3.8 xiB, xiB-64 PCIe Interface
for details on the camera connector and input requirements.
The power required to run the camera varies on the camera model from 9-29W. Ximea sells a power supply to run the cameras.
PN: BACS30M-24-C8 or BACS60M-24-C8.
3.2.
General Specification
3.2.1.
Environment
Description
Value
Optimal ambient temperature operation
+10 to +25 °C
Ambient temperature operation
+0 to +50 °C
Ambient temperature for storage and transportation
-25 to +70 °C
Relative Humidity, non-condensing
80 %
table 3-1, environment
Housing temperature must not 65°C. The following parameters are not guaranteed if the camera is operated outside
the optimum range:
•
Dark current
•
Dynamic Range
•
Linearity
•
Acquisition and readout noise
•
S/N ratio, durability
3.2.2.
Firmware / Host driver / API features
Description
Value
Interpolation
Proprietary
White balance coefficients ranges
0.0 to 3.9
Sharpness filter
-400 to 400 %
Gamma
0.3 to 1.0
Full color correction matrix (3+1)x3 coefficients ranges
-3.9 to 3.9
table 3-2, firmware / API features
More details on API/SDK features are available at
XIMEA support pages: http://www.ximea.com/support