23
The operation panel of inverter in
adopts three-level menu structure to carry out operations
our company
such as parameter setup .
The three-level menu includes function parameter set (level 1 menu)
function code (level 2 menu)
code setup value (level 3 menu) . Refer to Fig.4-2 for the operation procedure .
function
Fig.4-2 Operation Procedure of three-level Menu
Note : When operating on level 3 menu , press FUNC key or ENTER key to return to level 2 menu . The
difference between FUNC key and ENTER key is described as follows : Pressing ENTER key will save
the setup parameter and return to the level 2 menu and then automatically turn to the next function code ,
return to level 2 menu without saving the parameter , and it will
while pressing FUNC key will directly
return to the current function code .
Example : Modify the function code FB.02 from 10.00Hz to 15.00Hz . (The bold-type word indicates
the flashing bit)
FUNC
Program key
Entry and exit of primary menu
ENTER
Confirmation key
Enter the menu interfaces level by level ,and confirm the set parameters .
RUN
Running key
It is used to start the running of the inverter under keyboard control mode .
STOP/RESET
Stop/Reset
Press the button to stop the running in the running status and reset the operation in the
fault alarm status .
S
S key
F6.00=0 S key disabled
F6.00=1 Forward rotation jog operation(set outfactory)
F6.00=2 Reverse rotation operation
F6.00=3 Clear the data of exact stop process
Select the displayed parameters in turn on the stop display interface and running
display interface , and select the modification digit of parameters when modifying
parameters .
Shift key
Increase key
Increase of the data or function code
Decrease key
Decrease of the data or function code
Fig.4-3 Examlpe of Parameter Editing Operation
4
Keyboard button description
、
4.2
Description of function code viewing and modification methods
Function Code
Modification
Function Code
Modification
Parameter Set
Modification
Data Display
First-level Menu
Second-level Menu
Third-level Menu
Stop Display
Button
Name
Function
Chapter 4 Operation and Display