F9.00
PID control mode
setup
The third part ot LED
:
PID action direction
0
positive action
:
1
reverse action
:
The second part of LED
source
:
PID feedback
0
AI1
:
1
AI2
:
2: AI1+ AI2
3: AI1- AI2
4
Min{AI1
AI2}
:
,
5
Max{AI1
AI2}
:
,
6
Pulse setup
DI
:
(
)
7
Communication setup
:
The first part of LED: PID reference source
0
panel potentiometer
:
1
PID digial reference (F9.02)
:
2
AI1
:
3
AI2
:
4
Pulse setup
DI
:
(
)
5
Communication setup
:
F9.01
PID reference
feedback range
0
9999
~
1
1
1000
001
○
F9.02
F9.12
F9.04
F9.14
F9.05
F9.15
F9.03
F9.13
PID
PID
reference
digital reference
0
F9.01
~
0
F9.01
~
Note : To realize the switch
with other PID reference source by
setting external terminal as 25 .
1
1
500
500
○
○
second digital
F9.06
F9.16
F9.07
F9.08
F9.09
F9.10
F9.11
Proportional gain P
Integration time I
Deviation limit
PID preset frequency
PID preset frequency
keep time
0.0
100.0%
0.0% :
close P
~
0.1
100.0s
100.0s : close I
~
0.0 50.0%
~
0.0Hz
upper limit frequency
~
0.0
3600.0s
~
1
0.01Hz
0.1s
0.1%
0.1s
0.0%
0.00Hz
20
0%
.
2.0s
0.0s
○
○
○
○
PID feedback
disconnection
detection
The second part of LED
action mode
:
1
00
0
enter PID feedback disconnetcion
fault state
display E.6
:
(
)
1
according to F5.05 setup stop mode
to stop
:
36
Sleeping frequency
0.0Hz
~the maximum frequency
0.01Hz
0.0Hz
Sleeping protract
0.0 3600s
~
0.1s
60.0s
Awakening threshold
0.0 100.0%
~
0.1%
0.0%
Awakening protract
0.0 60.0s
~
0.1s
0.5s
○
○
○
○
Group F9
PID Function
Reserved function
*
-
-
-
Differential time D
0.0
10.00s
0.0s :
close D
~
0.01s
0.0s
○
Differential amplitude
0.0
100.0%
~
0.1%
5.0%
○
Chapter 5 Function Parameter Table
Factory default
value
Modif-
ication
Function
code
Name
Setup range
Minimum unit