The operation methods of exact stop
:
1
data display and modification
If the parameter is set in reason , the inverter can display and
modify the data just like operating the counter ,the length
controller and the timing .
:
Firstly, set the corresponding parameter of exact stop as
enabled by setting parameter F6.01 to F6.04.
e.g.: set F6.02 = 96 to make the setup length and the actual
length enabled .
In the monitor mode of the state parameter, you can switch
display content via shift key . When it switches into
display actual length , you can modify it via Increase key
/Decrease key of the operation panel, exit it by pressing
FUNC key or ENTER key. The actual length value will
Actual counting value FV.16 is calculated via the pulse signal
input by the X6 input terminal , and it needs to set the X6
terminal to count input terminal .
When the actual counting value reaches the setup counting value
, the output terminal will output signal of the setup counting value.
The counter will stop counting .
When the actual counting value reaches the designated counting
value, the output terminal will output signal of the designated
counting value . The counter will continue counting till the
setup counting value
is reached .
“
”
The designated counting value FA.09 should not exceed the
setup counting value FA.08 .
The function is shown
the following figure
:
as
1
9999
~
1
~
9999
When the actual length FV.18 exceeds the setup length FA.05 ,
the output terminal
Length arrival terminal
will output ON
signal (refer to Group F4 function code).
“
”
Exact stop mode: In term of several control
produce quantity which is in common use to realize inverter
automatical stopping , and you can use operation panel to
replace counter , length controller , timing which are widely
used in machine facilities .
1
3
4
5
6
7
8
Counting Pulse
Setting Count
X5
C1
0
Fixed length control as one of the exact stop modes,
.
For detail setting, refer to the parameter description of FA.11 .
when it
arrivals the setup length, the inverter stops automatically
2
1000
1000
FA.08
FA.09
FA.11
0
Chapter 6 Parameter Description
Factory
default value
FA.05
1.000km
Setup length
0
65.535km
~
Setup range
Factory
default value
FA.06
1.000km
Designed length
0
65.535km
~
Setup range
Factory
default value
Factory
default value
Factory
default value
FA.07
100.0
Number of pulses
each meter
0.1
6553.5
~
Setup range
Setup range
Setup range
Setup range
The setup (designed)length ,actual length and
are mainly used for fixed length control .
For the image parameter FV.19 of FA.05 and FA.06 , their
meanings are the same , just one method added to easy
modification and viewing. (Please refer to the
description of FA.11 exact stop mode .)
number of
pulse each meter
parameter
For image parameter FV.17 of FA.08 , its meaning is the same
, just one method added to easy parameter modification and
viewing. (Please refer to the description of FA.11 exact stop
mode .)
The length is calculated via the pulse signal input by the X6
input terminal , and it needs to set the corresponding input
terminal to length count input terminal .
Actual length
length count input
numbers/number
of pulse each meter
=
pulse
Setup counting value
Designated counting
value
Designated
Count
C2
0
Fig. 6-22 Schematic Diagram for Setup Counting Value
Reference and Designated Counting Value Reference
Counter control as one of the exact stop modes , when it arrivals
the setup length , the inverter stops automatically .
For detail setting ,refer to the parameter description of FA.11 .
Factory
default value
Factory
default value
Internal timing setup
running time
24.000h
FA.10
Setup range
0.0
65.535 h
~
For image parameter FV.21 of FA.10 , its meaning is the same
, just one method added to easy parameter modification and
viewing. (Please refer to the description of FA.11 exact stop
mode .)
When actual running time FV.20 exceeds the setup running
time FA.10 , the output terminal
Setup running time arrival
terminal
will output ON signal (refer to Group F4 function
code).
“
”
Timing stop control as one of the exact stop modes , when it
arrivals the setup length , the inverter stops automatically .
For detail setting, refer to the parameter description of FA.11 .
Exact stop mode setup
disabled
setup counting value arrival
setup length arrival
setup running time arrival