46
All the work of changing the battery should carried out according to the description of user’s
manual from the factory. When reinstall the battery, should adopt measures to make the
battery connecting, orientation and fixation correctly. Do not put tools and other metal
substance on the lidless battery.
Without the special approval (for example the truck factory), the electrical motor truck should
not change the battery with different voltage, weight or size.
It is obliged to use the battery stated by the factory. It is obliged to prepare the facility for
changing battery safely. When hanging up the battery using hoisting equipment, it is necessary
to use insulated steeve.
If adopting chain hoist, it is necessary to equip chain box. If adopting chain block, the lidless
battery should be covered by a piece of rubber blanket or other insulated materials, to prevent
the short circuit of chain and the connecting wire or connecting terminal between the battery
lattice.
14.1.4.6
The invalid or damaged truck
If finding the motor industrial truck existing insecurity factors, it should stop using and give
away on the spot. After repairing and recovery to the safety conditions, it can be reused.
14.1.4.7
Accident
Once the accident happens, for example the staff injures, the truck damages the building or the
equipment, firstly should organize salvage, do best to protect the accident field and report to
the governor.
14.1.5
Operating conditions
14.1.5.1 Channel and stacking field
The ground of the operating field should have enough carrying capacity, and it is necessary to
maintain it well not to influence the truck operating safely.
The transporting channel of the truck should have well visual field, and it is easy to turn, and no
grade, steep slope, narrow channel and low roof board. The outline or the borderline must be
clear.
In the road where it is easy to meet the stepping truck, the width of the channel should be
adjusted.
Advising the grade of the channel should not over 10%, the top and the bottom of the slope
should transit smoothly, to prevent the load vibration or the bottom of the truck from colliding
the ground.
When the grade is over 10%, installing a sign is advised.
If the truck is in operation (transport) and the load block off the sight, when the vehicle is
operating, the load should located on the backward of the truck operation direction.
For example: in some conditions (for example stacking and climbing), when the vehicle is
operating, the load is required on the forward of the vehicle operation direction. Then, the
driver should drive the vehicle carefully. It is necessary to attend: if the operation condition
require, should equip accessory (assistant) equipment or assistant.
The passage, road, runway, floor or slope should maintain good operating conditions, to
prevent the truck or the load from being damaged, and to prevent reducing the stability of the
vehicle.
In dangerous state, including the barrier danger on the top, should mark on the clear location.
The fire fighting passage, the upstairs passage and the fire fighting equipment should maintain
expedite.
14.1.5.2 Gangplank or transition board
Содержание CDDR
Страница 1: ...CDDR Electric Pallet Stacker Operation Manual Parts Catalogue 2010 06...
Страница 6: ...2 1 Configuration diagram 1 1 CDDR configuration diagram...
Страница 7: ...3...
Страница 44: ...40 A1 V1 1Z P1 Hydraulic Principle Diagram standard 10X2...
Страница 45: ...41 Solenid Valve Main Motor Hydraulic Principle Diagram high standard...
Страница 46: ...42 Standard Full Electric Pallet Stacker...
Страница 47: ...43 High equipped all electric Pallet Stacker...
Страница 60: ...56 Customer advisement feedback Items Occurrence time Location of faults Faults causes Trouble shooting Remarks...