MNC-0300-011
10 of 26
Revision H
Unpacking and Installation
Monitor and Control Connector
To externally control the amplifier a M&C interface is provided. The
connector is a 32-pin MIL style waterproof connector.
The Monitor and Control connector provides these interfaces for the use
of the customer:
•
COM1 — RS-232 Serial Port.
•
COM2 — RS-422/ RS-485 Serial Port.
•
Two sets of Form “C” Relay contacts for Summary Fault indication.
•
RF Inhibit Control.
•
24 VDC @ 100 mA maximum.
•
15 VDC for monitoring purposes only.
•
Hardware Address Select (digital SSAs only).
Monitor and Control Pinouts
Figure 4 shows the pin layout; Table 1 lists the pinouts for the typical
Digital Monitor and Control Connector on the Antenna Mount Power
Amplifier.
Figure 5 shows the pin layout and Table 2 lists the pinouts for the typical
Analog Monitor and Control Connector on the Antenna Mount Power
Amplifier.
Figure 4, Digital M&C Connector Pin Layout
Содержание XTS-200C
Страница 2: ...Document Number MN5 0281 002 Date June 2004 Revision B XTS 200C Operation and Installation Manual...
Страница 10: ...MNC 0000 010 2 Revision A6...
Страница 22: ...MNC 0100 007 4 Revision C Overview Figure 1 Typical Solid State Power Amplifier ODU Antenna Mount Block Diagram...
Страница 38: ...MNC 0200 004 14 of 14 Revision C Safety Sicherheit...
Страница 49: ...MNC 0300 011 11 of 26 Revision H Unpacking and Installation Figure 5 Analog M C Connector Pin Layout...
Страница 64: ...MNC 0300 011 26 of 26 Revision H Unpacking and Installation...
Страница 72: ...Operation MNC 0400 012 8 of 8 Revision C...
Страница 104: ...MNC 0500 010 32 Revision D Solid State Power Amplifier Communication and Protocol...
Страница 122: ...MNC 0700 001 6 Revision F Service and Repair...
Страница 131: ......
Страница 132: ......
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ......
Страница 137: ......
Страница 138: ......
Страница 139: ......
Страница 140: ......
Страница 144: ...MNC 0000 039 4 of 12 Revision 2 ODU SSPA Power Supply Removal...
Страница 152: ...MNC 0000 039 12 of 12 Revision 2 ODU SSPA Power Supply Removal...
Страница 155: ...MNC 0000 003 3 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Страница 156: ...MNC 0000 003 4 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Страница 160: ...MNC 0000 002 4 Revision A Protocol Adendum Block Upconverter...
Страница 165: ...MNC 0000 015 5 of 8 Revision C Operation Addendum Block Upconverter Figure 3 Detailed BUC Block Diagram...
Страница 168: ...MNC 0000 015 8 of 8 Revision C Operation Addendum Block Upconverter Figure 4 Drift Compensation Block Diagram...