Solid State Power Amplifier Communication and Protocol
High RF Trip
Command Byte
: 'M'
Function
: Sets a High RF trip point. If output power exceeds the set point, an alarm or
fault is generated provided. By default the trip point is not enabled until this trip point is
set.
Parameter
: "AXXXX" to set an Alarm trip point, "FXXXX" to set a Fault trip point, “D” to
disable.
XXXX is the desired trip point in Watts.
Reflected RF Trip
Command Byte
: 'O'
Function
: Sets a Reflected RF trip point. If reflected power exceeds the set point, an
alarm or fault is generated, as specified by the user. (Note: A hardware Reflected RF
Trip Point is pre-set at the factory. You cannot adjust the hardware trip point by
changing the software trip point). By default, the trip point is not enabled until this trip
point is set.
Parameter
: "AXXXX" to set an Alarm trip point, "FXXXX" to set a Fault trip point, “D” to
disable.
XXXX is the desired trip point in Watts.
Содержание XTS-200C
Страница 2: ...Document Number MN5 0281 002 Date June 2004 Revision B XTS 200C Operation and Installation Manual...
Страница 10: ...MNC 0000 010 2 Revision A6...
Страница 22: ...MNC 0100 007 4 Revision C Overview Figure 1 Typical Solid State Power Amplifier ODU Antenna Mount Block Diagram...
Страница 38: ...MNC 0200 004 14 of 14 Revision C Safety Sicherheit...
Страница 49: ...MNC 0300 011 11 of 26 Revision H Unpacking and Installation Figure 5 Analog M C Connector Pin Layout...
Страница 64: ...MNC 0300 011 26 of 26 Revision H Unpacking and Installation...
Страница 72: ...Operation MNC 0400 012 8 of 8 Revision C...
Страница 104: ...MNC 0500 010 32 Revision D Solid State Power Amplifier Communication and Protocol...
Страница 122: ...MNC 0700 001 6 Revision F Service and Repair...
Страница 131: ......
Страница 132: ......
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ......
Страница 137: ......
Страница 138: ......
Страница 139: ......
Страница 140: ......
Страница 144: ...MNC 0000 039 4 of 12 Revision 2 ODU SSPA Power Supply Removal...
Страница 152: ...MNC 0000 039 12 of 12 Revision 2 ODU SSPA Power Supply Removal...
Страница 155: ...MNC 0000 003 3 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Страница 156: ...MNC 0000 003 4 of 4 Revision B Operation Addendum SSPA M C Termination Cable...
Страница 160: ...MNC 0000 002 4 Revision A Protocol Adendum Block Upconverter...
Страница 165: ...MNC 0000 015 5 of 8 Revision C Operation Addendum Block Upconverter Figure 3 Detailed BUC Block Diagram...
Страница 168: ...MNC 0000 015 8 of 8 Revision C Operation Addendum Block Upconverter Figure 4 Drift Compensation Block Diagram...