12
CN3200 Dual Band Routing Modem - Installation Guide - G7604 - Release 1.0
These steps set up the CN3200 Dual Band Routing Modem for use.
After completing these configuration steps, the CN3200 Modem will be fully functional and ready for
operation. It will broadcast on the configured channel. The CN3200 Modem will provide any Internet-
ready device the ability to connect wirelessly to the xMax network, using a secure connection on a
connected WiFi router.
Devices may also be connected to the xMax network through a wired Ethernet connection to the
CN3200 Modem. For more information,
see
Wired Internet Connectivity and Setting Up a WiFi Hotspot
on page
22
.
NOTES
This procedure should be completed before installing the CN3200 Modem in a service location.
The setup sequence assumes that the CN3200 Modem device is in factory-default
configuration and has not been previously configured.
IMPORTANT: BEFORE YOU CONTINUE
Antennas or dummy loads
MUST
be connected to the two top Tx RF ports.
Both Tx RF ports
MUST
be properly terminated
before power (PoE) is applied to the unit.
Applying power without proper RF port
termination might damage the unit
and void the product warranty.
The CN3200 Dual Band Routing Modem is powered through the Ethernet cable. PoE (Power-over-
Ethernet) is a standardized system which passes electrical power along with data on Ethernet cabling.
After terminating the Tx RF ports, connect the provided PoE++ Power Supply as shown:
DO NOT
plug the power cord into the AC outlet until directed.
110-240 VAC,
50/60 Hz
PoE++
Power
Supply
PoE Surge
Protector
ETHERNET DATA
POWER plus DATA
GROUND