![xFusion Digital Technologies FusionServer G8600 V7 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/xfusion-digital-technologies/fusionserver-g8600-v7/fusionserver-g8600-v7_manual_3326749021.webp)
Identifier
Indicators
and Buttons
State Description
54 V PSU
indicator
● Off: There is no AC input.
● Blinking green (1 Hz):
– The input is normal, and the PSU shuts
down 54 V output due to the INSTALLED
signal.
– The input is normal. The PSU enters the
shutdown mode because the PSON#
signal is at high level.
– Input overvoltage or undervoltage occurs.
– The standby PSU is in cold standby mode.
– The PSU enters deep sleep mode.
● Blinking green (4 Hz): Online upgrade is in
progress.
● Steady green: The input and 54 V mains
output are normal.
● Steady orange:
– Normal input and overtemperature
protection
– Output overcurrent or short-circuit
– Output overvoltage
– Short-circuit protection
– Component failure (excluding failure of all
components)
5.1.3 Port
Port Positions
●
8 x 2.5" drive configuration
FusionServer G8600 V7 Server
Technical White Paper
5 Hardware Description
Issue 03 (2023-09-15)
Copyright © xFusion Digital Technologies Co., Ltd.
14