![xFusion Digital Technologies FusionServer G8600 V7 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/xfusion-digital-technologies/fusionserver-g8600-v7/fusionserver-g8600-v7_manual_3326749010.webp)
●
The server supports hot-swappable SAS/SATA drives for which RAID 0, 1, 1E,
10, 5, 50, 6, or 60 can be configured (the RAID level depends on the RAID
controller card used). It also uses a supercapacitor to protect the RAID cache
data against power failures.
●
The panel provides UID or Healthy LED indicators and a fault diagnosis LED
indicator. The iBMC WebUI displays key component status, enabling technical
experts to quickly locate faulty or potentially faulty components, which simplifies
maintenance, speeds up troubleshooting, and improves system availability.
●
The panel provides the iBMC direct connect management port to support local
iBMC O&M, improving O&M efficiency.
●
Up to six 54 V PSUs (N+M redundancy supported) and two 12 V PSUs (N+N
redundancy supported) reduce 54 V to 12 V power conversion and power
consumption.
●
The GPU heat dissipation system is decoupled from the system heat dissipation
system. The two computing planes are designed with independent air ducts to
provide an optimal heat dissipation solution.
●
The onboard Intelligent Baseboard Management Controller (iBMC) can
continuously monitor system parameters, trigger alarms, and take recovery
measures to minimize shutdown.
●
For more information about the warranty, see
.
Manageability and Security
●
The built-in iBMC monitors system operating status and provides remote
management.
●
A password is required for accessing the BIOS, ensuring system boot and
management security.
●
The Network Controller Sideband Interface (NC-SI) feature allows a network port
to simultaneously serve as a management port and a service port. The NC-SI
feature is disabled by default and can be enabled on the iBMC or BIOS.
NO TE
The service port with NC-SI enabled supports the following configuration:
● Configuring any network port on the OCP 3.0 NIC or PCIe NIC (with NC-SI enabled).
● Enabling, disabling, and setting a virtual local area network (VLAN) ID for this port.
The VLAN ID is
0
and disabled by default.
● Configuring IPv4 addresses (IPv4 address, subnet mask, and default gateway) and
IPv6 addresses (IPv6 address, prefix length) for this port.
●
The integrated Unified Extensible Firmware Interface (UEFI) improves setup,
configuration, and update efficiency and simplifies fault clearance.
●
Intel Execute Disable Bit (EDB) function prevents certain types of malicious
buffer overflow attacks when working with a supported OS.
●
Intel
®
Trusted Execution Technology prevents malicious software attacks based
on hardware, prevents the firmware on the device from being maliciously
modified, and prevents unauthorized boot block execution.
●
Intel
®
Software Guard Extensions (Intel
®
SGX) technology allows applications to
run in their own independent space without being affected by other software
running in the system, thereby enhancing security.
FusionServer G8600 V7 Server
Technical White Paper
2 Features
Issue 03 (2023-09-15)
Copyright © xFusion Digital Technologies Co., Ltd.
3