15 Problem Solving
372
Other
Restrictions
This section explains the restrictions that apply while using SMB.
Machine settings
• The IP address is a unique address administered system-wide. Consult with the
system administrator when setting the necessary parameters.
• The subnet mask and gateway settings may also be required, depending on the
networking environment. Consult with the system administrator when setting the
necessary parameters.
• When a port is enabled and there is insufficient memory, the port may be disabled
automatically. In this case, disable all unused ports and reallocate the memory.
• The [Receiving Buffer - SMB] memory allocation needs to be set in response to the
operating environment. If the memory allocation is too small, it may prevent
receiving messages.
Client settings
• The IP address is a unique address administered system-wide. Consult with the
system administrator when setting the necessary parameters.
When the machine is switched off
The following actions take place when the machine is switched off.
• When [Receiving Buffer - SMB] is set to [Spool to Memory]:
All print data spooled in machine memory, including the data currently being printed,
is deleted. There is no print data on the machine when the machine is switched on.
However, if the machine is switched off immediately after a print request, the print
data may be stored on the client. In this case, the print request can be reissued when
the machine is switched on, and the print data is printed on the machine.
• When [Receiving Buffer - SMB] is set to [Spool to Hard Disk]:
All print data spooled on the machine hard disk, including the data currently being
printed, is retained. A print request can be reissued when the machine is switched
on, and the print data is printed on the machine.
The document owner is
invalid.
Check whether the owner of
the selected document
matches the Windows log-in
name.
Use the owner name of the
document to log in to
Windows, and then delete the
document.
Service Pack 4.0 or later is
not installed in the system.
(In Windows NT 4.0)
Check the Service Pack
version displayed when you
start Windows NT 4.0.
Install Service Pack 4.0 or
later.
Problem
Action
Job history displays a
message that the document
name is undefined instead of
the correct job name.
Change the [Receiving Buffer - SMB Spool] setting from
[Memory] to [Hard Disk].
Cause
Confirmation Method
Action
Содержание WorkCentre 5230A
Страница 1: ...User Guide ME3612E4 1 System Administration Guide XE3022EN0 2...
Страница 12: ...12...
Страница 28: ...2 Paper and Other Media 28...
Страница 62: ...5 Machine Status 62...
Страница 148: ...6 Setups 148...
Страница 232: ...7 CentreWare Internet Services 232...
Страница 274: ...8 Printer Environment Settings 274...
Страница 282: ...9 E mail Environment Settings 282...
Страница 430: ...15 Problem Solving 430...
Страница 444: ...16 Appendix 444...