Fault Codes
413
027-504
An error occurred in the SMTP server. Try again. Contact the Xerox Welcome
Center if the problem persists.
027-513
The machine failed to transfer data via SMB using the Scan to PC service
because access to the SMB server was not permitted.
When the server is Macintosh, a folder with the same name as the specified file
may exist on the server.
Change the settings so that a file or a folder can be read and written at the save
location.
When the server is Macintosh, change the folder name on the server, or the file
name to be transferred.
027-514
The machine failed to transfer data via SMB using the Scan to PC service
because the machine could not resolve the host name or the server name of the
SMB server when accessing DNS.
Check the connection to DNS. Check if the SMB server name has been
registered on DNS.
027-515
During data transfer via SMB using the Scan to PC service, access to DNS
failed because the DNS server was not set correctly.
Set the DNS server address. Or, specify the destination SMB server address
using its IP address.
027-516
The machine failed to transfer data via SMB using the Scan to PC service
because the SMB server was not found.
Take one of the following actions, and try again:
• Check the following to see if the destination SMB server and the machine are
set up properly for network communication:
- Check if the network cables are plugged in securely.
- Check the TCP/IP settings.
- Check the communication status of port 137 (UDP), port 138 (UDP), and
port 139 (TCP).
• Check the following to see if the computer correctly works as an SMB server.
- Check if the file sharing service for Microsoft Network is activated.
- Check if [NetBIOS over TCP/IP] for TCP/IP is activated.
- Check if the file sharing service (using communication through port 137
(UDP), port 138 (UDP), and port 139 (TCP)) are authorized for the Firewall
settings.
• For communication that exceeds the subnet, check the WINS server settings,
and check if the server address can be resolved correctly.
• For Windows NT 4.0 Server/Workstation, use the following steps to see if the
NetBIOS interface device is activated on the destination SMB server:
1. Select [Start] > [Settings] > [Control Panel].
2. Display [Services], then select [Messenger].
3. Select [Startup] > [Auto] > [OK], then select [Close].
4. Select [Devices] in [Control Panel], then select [NetBIOS Interface].
5. Select [Startup] > [Auto] or [Manual] > [OK], then select [Close].
6. Reboot the computer.
027-518
The machine failed to transfer data via SMB using the Scan to PC service
because the specified password was incorrect.
When the server is Macintosh, the specified user may not have been registered
as a user who is permitted to use Windows Sharing.
Check the password for the shared folder.
When the server is Macintosh, specify a user who is permitted to use Windows
Sharing.
Code
Description and Remedy
Содержание WorkCentre 5230A
Страница 1: ...User Guide ME3612E4 1 System Administration Guide XE3022EN0 2...
Страница 12: ...12...
Страница 28: ...2 Paper and Other Media 28...
Страница 62: ...5 Machine Status 62...
Страница 148: ...6 Setups 148...
Страница 232: ...7 CentreWare Internet Services 232...
Страница 274: ...8 Printer Environment Settings 274...
Страница 282: ...9 E mail Environment Settings 282...
Страница 430: ...15 Problem Solving 430...
Страница 444: ...16 Appendix 444...