Optional Devices Chart
The following table lists the number of ADDITIONAL plates required
for the various optional devices. The number of plates listed does NOT
include the base press configuration.
NOTE:
The Interface Module is required with any system configuration that
has one or more finishing device, except the Offset Catch Tray (OCT) and
the BR Finishers.
Optional feeding / finishing device
Required
Mobility Kits
High Capacity Feeder (HCF)
(letter size)
1 kit
1-tray Oversized High Capacity Feeder (OHCF)
2 kits
Advanced High Capacity Feeder (Advanced HCF)
2 kits
BR Finisher
1 kit
BR Booklet Finisher
1 kit
Interface GBC AdvancedPunch
1 Kit
Interface High Capacity Stacker (HCS)
3 kits
Interface Standard Finisher (without C/Z
Folder)
2 kits
Interface Standard Fi C/Z Folder
2 kits
Interface Booklet Maker Finisher (without
C/Z Folder)
2 kits
Interface Booklet Maker Fi C/Z
Folder
3 kits
SquareFold Trimmer Module
1 kit
Standard Finisher Plus* without C/Z Folder
*Includes Finisher Module and Finishing Transport
3 kits
Standard Finisher Plus* with C/Z Folder
*Includes Finisher Module and Finishing Transport
4 kits
2-Knife Trimmer
2 kits
Electrical Requirements
All machine optional accessories and print servers should be placed within
6 feet (3 meters) of wall outlets. Ensure that there are enough wall outlets
available for optional accessories and the print server.
Press Electrical Requirements
Electrical requirements must be satisfied prior to equipment delivery. The
Press requires a dedicated 20 Amp service.
Item
Main processor
Nominal Voltage
North America (NA): 208-240 VAC (XC) -
10%/+6%
Europe: 220-240 VAC (XE) ±10%
Amperage circuit
Current rating
20*
*Requires a 20 circuit and receptacle
16
Cycles
50/60 Hz Single Phase
Frequency (Hz)
NA: 50/60 ±3%
Europe: 50 ±3%
In rush current
100A or less
Item
Main processor
Power
consumption
NA: 208V, 3.66KW or less
NA: 240V, 4.224KW or less
Europe: 220V, 4.4KW or less
Europe: 240V, 4.8KW or less
Power Cord Length
10 feet/3 meters
Plug/Receptacle
Diagram
North America Plug: NEMA 6-20P
North America Receptacle: NEMA 6-20R
A single power cord (USA plug and receptacle
diagram shown above) is required for the
press.
Europe: PCE Shark 023-6 Plug
Europe: receptacle that mates to the PCE Shark
023-6 plug
Electrical Requirements for Optional Devices
NOTE:
HCF, BR Finisher, and BR Booklet Finisher plug directly into press
and require no additional power receptacle.
NOTE:
Use surge protection only as required and is the responsibility of
the customer.
International Requirements
Each optional feeding and finishing device requires an additional 100-
240 VAC or 208-240 VAC country-specific power receptacles.
USA Requirements
Each optional feeding and finishing device requires one additional
NEMA 5-15R or 5-20R receptacle; refer to the following diagram and
table.
Item
1-Tray OHCF / Advanced HCF
Current/run power
3 amps/65 watts
Voltage (VAC)
1-Tray OHCF – 100-120V 2.5A, 220-240V 1.5A
Advanced HCF – 100-120V 5A, 220-240V 3A
Power cord
length
8.2 feet/2.5 meters
Receptacle NEMA
part number
5-15R or 5-20R
NOTE:
Use surge protection only as required, and it is the responsibility of