2-32
Phaser 3300MFP Service Manual
Theory of Operation
Fuser AC Power Control
AC power to the Fuser is controlled with a Triac, a semiconductor switch. The
ON/OFF control is operated when the gate of the Triac is turned on/off by
Phototriac (insulating part).
When the ‘HEATER ON’ signal is turned on at engine, the LED of PC501
(Photo Triac) flashes. From the flashing light, the Triac (light receiving part)
takes the voltage, and the voltage is supplied to the gate of Triac and flows
into the Triac. As a result, the AC current flows in the lamp to create heat.
When the signal is off, the PC501 is off, the voltage is cut off at the gate of
Triac. The Triac is turned off, interrupting power to the lamp.
■
Triac (Q501) feature: 24 A-LV model/16 A-HV model, 600 V SWTCHING
■
Phototriac Coupler (PC501)
■
Turn On If Current: 15 mA ~ 50 mA (Design: 16 mA)
■
High Repetive Peak Off State Voltage: Min 600 V
Содержание Phaser 3300
Страница 1: ...Phaser 3300MFP Multi Function Printer Phaser 3300MFP Service Manual...
Страница 2: ......
Страница 16: ...xiv Phaser 3300MFP Service Manual...
Страница 81: ...3 Chapter Error Messages and Codes In this chapter Introduction Jam Error Codes Error Messages...
Страница 92: ...3 12 Phaser 3300MFP Service Manual Error Messages and Codes...
Страница 118: ...4 26 Phaser 3300MFP Service Manual General Troubleshooting...
Страница 136: ...5 18 Phaser 3300MFP Service Manual Print Quality Troubleshooting...
Страница 140: ...6 4 Phaser 3300MFP Service Manual Adjustments and Calibrations...
Страница 272: ...9 38 Phaser 3300MFP Service Manual Parts List...
Страница 273: ...10 Chapter Wiring Diagrams Block Diagram WD 2 Connection Diagram WD 3 Power Signal Interconnection Diagrams...
Страница 288: ...10 16 Phaser 3300MFP Service Manual Wiring Diagrams...
Страница 289: ...A Appendix Appendix Contents Phaser 3300MFP Menu Map Acronyms and Abbreviations...
Страница 295: ......