6-12
XEROX DFC165 & DWC165c Service Manual
6.2 CHECKS AND ADJUSTMENTS
6.2.1 Checking the direct voltages
1) Remove the power supply/NCU assembly (see section 7.2.3) without disconnect-
ing it from the motherboard
2) Measure the direct voltages at connector J2 on the power supply board.
Fig. 6-5
P F
+28 VDC
GND
GND
GND
+24 VDC
+5 VDC
+12 VDC
-12 VDC
J2