5-16
XEROX DFC165 & DWC165c Service Manual
5.4
REMOTE DIAGNOSTICS
Remote diagnostics is a
long-distance service
enabling a main station, consisting
of a facsimile machine connected to a PC (called a
"master station
"), to perform
diagnostic operations on any peripheral facsimile machine in the same family (called
a
"slave station"
) - providing it has been
enabled
to do so
previously
- to eliminate
problems that have arisen on the slave.
This facsimile machine can only be enabled as a "
slave station
" in remote diagnostic
sessions, that is:
-
transmit
a series of data that includes the
setup parameters
after a request has
been made in polling mode by a "master station"
-
have
these parameters changed locally
(i.e. on the "master station"
-
receive the modified data
to replace the current data.
5.4.1 Enabling the Facsimile Machine as a "Slave Station"
Enabling the facsimile machine to "slave" operation is possible by setting to
1
the bit
5
of software switch SW10
(see section 4.1).
To use this function, it must be enabled by setting the
REMOTE CONTROL
setup
parameter in the DIAGNOSTICS submenu of the main INSTALLATION menu (see
section 3.2.1) to
YES
.