Rover User Manual Version 3.0
37
Removing the ROBY float
Xeos does not recommend removing the ROBY’s float unless it is necessary. The unit can be used
and disassembled while the float remains on.
1.
Using a pair of internal snap ring pliers, stretch the top ABS brace until it can be slid off
the ROBY’s top cylinder.
2.
Repeat step one for the bottom brace.
3.
After both braces have been removed, the float can be slid off the ROBY.
Recovery and Storage
Once, the Rover is recovered, it is important that it be stored and maintained properly for future
deployments.
As soon as possible after the Rover is recovered, all batteries should be removed and discarded.
The Rover should be cleaned and inspected for corrosion or water ingress. O-rings should be
visually inspected. Any concerns should be discussed with Xeos support (+1-902-444-7650 or
[email protected]) prior to storage.
The Rover should be stored as follows:
Dry location
Assembled,
without batteries
but with O-rings in place
Ambient temperature of -40° C to +85° C
Either horizontal or vertical storage is permitted