Image processing options
The Wildcat camera has several optional on-board image processing algorithms.
On-board algorithms
Features
NUC (Non-Uniformity Correction)
FPN (Fixed Pattern Noise) correction
PRNU (Photo-Response Non-Uniformity)
correction
Bad pixel replacement
Dynamic range clipping
Gain and offset control
Manual mode control options
Automatic mode control options
Outliers control options
Input histogram control options
Black hot control
White hot / black hot toggle
Image overlays
Footer
Test patterns
Additional software-level image processing options are available in Xeneth. Consult the
Xeneth User Manual in the Xeneth installation directory for more detailed information.
The camera has a global override to enable or disable all on-board image processing
algorithms. By setting
Image correction control
– Raw mode
to
True
, the camera is forced
to output the raw video signal it receives from the sensor, without any processing or
correction.
To use on-board image processing, ensure
Raw mode
is set to
False
.
To use software-level processing, set
Raw mode
to
True
.