XCPC-9100
Xembedded, Inc.
25
Write FRU Data
This command writes the specified byte or word to the FRU Inventory Information area. No parsing of the FRU
data is performed by the IPMI subsystem management software is responsible for creating valid FRU data
structures and writing the data to the FRU area.
NetFn 0x0A, Cmd 0x10
Byte Value
Data
Field
Comments
Request-Data 1
XX
h
FRU device ID,
2
XX
h
FRU Inventory offset to
read Low Byte
3
XX
h
FRU inventory area size in
bytes, High byte
Offset is in words or bytes
per device access type
returned in the FRU
Inventory Area information
command.
4:3+N
XX
h
Data to Write
Response-data 1
00
h
Completion
code
00
h
- Successful
80
h
- Write Protected
2
XX
h
Count returned – 1 based
FRU Data Specification
The XCPC-9100 is pre-loaded with the following data at the factory.
Board Information:
Product : "CPC"
File ID : "MgtCtrl.bin"
Part : "CPC 9100"
Serial : <varies>
Manuf. : "Xembedded"
Product Information:
Product : "CPC"
Version : "01.01"
Part : "609100"
Manuf ID: "0x029117"
Manuf. : " Xembedded "
Содержание XPMC-9100
Страница 8: ...Introduction Figure 1 1 below shows the Architectural of the board 2...
Страница 14: ...Introduction 8...
Страница 20: ...Installation Guide XCPC 9100 Table 2 4 showing pin out of the J22 and J12 13...
Страница 21: ...Installation Guide XCPC 9100 Table 2 5 Pin out for the J23 and J13 14...
Страница 22: ...Installation Guide XCPC 9100 15 Table 2 6 Pin Out definition for J24 from PMC site 2...
Страница 23: ...Installation Guide XCPC 9100 Table 2 7 for the pin out of the J14 Rear I O for PMC site 1 16...